Trouble shooting
Fault
Possible cause
Compressor is
Be patient, it is most likely that the
not running.
compressor will start within a few
minutes.
Power for appliance is not plugged in
Power for stabilizer is not plugged in
Power for appliance is not switched on
Power for stabilizer is not switched on
Stabilizer power fuse has blown
Stabilizer 6 min. time delay is in
progress
Compressor is
The ventilation grille is blocked.
running, and
the temperature
is too high.
The lid is not closed properly.
The temperature in the room in which
the appliance is installed is too high.
No temperature
The Thermometer is broken.
is displayed.
There is not enough light for the solar
sensor.
Remedy
If this is not the case, check the
following:
Check that the power for appliance
is plugged in
Check that the power for stabilizer
is plugged in
Check that the power for appliance
is switched on
Check that the input voltage is
within the input range of stabilizer
Check fuse
Wait for the delay to end
- If the above is OK, call technical
supervisor.
Ensure unhindered air circulation.
Ensure that the lid is closed prop-
erly.
Shield the appliance against direct
sun light and ensure more ventila-
tion to the room.
Change the thermometer.
Turn on the light.