Connect the relevant components to
connection b.
Secure the cable with the strain relief
provided.
Close and screw on the lid of the con-
trol module.
If earthing cannot be ensured using
the fixing screws, connect the earth-
ing wire provided.
After all components have been in-
stalled, carry out an electrical safety
check in accordance with local regu-
lations (e.g. VDE 0701-1 in Germany).
en - Operating and installation instructions
Central extraction unit
The potential-free contact of the control
module can, for example, be used in
an EXT/EXTA model cooker hood that is
connected to a central extraction unit.
The contact can be used to actuate an
electrically operated shut-off valve ,
which is upstream of the central extrac-
tion unit.
The shut-off valve must be suitable for
switching with a potential-free normally
open contact.
The fan power is dependent on the fan
used and the design of the extraction
system. The fan power is not controlled
via the cooker hood control elements.
The components in the central extrac-
tion unit are not part of the Miele deliv-
ery programme.
If in any doubt, ask your building regula-
tions inspector prior to installation.