• The charging station may be inclined max. 8 cm to the rear
and max. 2 cm to the front.
• Remove any unevenness under the charging station. The
charging station must never sag.
• Make sure there is suffi cient distance to ponds, pools and
steps.
Laying the boundary wire
Lay the boundary wire (11) around the lawn area to be worked
by the lawn mower. You can do this as follows:
- Stake out the lawn area. Fasten the boundary wire (11) with
the hooks (13) (above ground).
- Stake out the hooks at a maximum distance of 1 m. Use addi-
tional hooks if the ground is uneven.
- Bury the boundary wire (11) in the ground (max. 5 cm deep).
The lawn mower crosses over the boundary wire by about
20 - 30 cm before it turns around and searches for a new
path. Install the boundary wire accordingly to prevent damage.
For the initial installation, we recommend marking out the
boundary wire (11) with the hooks (13) in case corrections
need to be made at a later date.
The mower works perfectly with a boundary wire length of
up to 200 m. Do not use a longer boundary wire.
• The lawn area must be bordered as a single enclosed area.
Course for laying line of boundary wire
• Any parallel boundary wires (11) installed at a distance of at
least 10 cm are identifi ed as an obstacle by the lawn mower
and are evaded.
equal to or greater than 10 cm (3.94 inches)
• Any parallel boundary wires (11) at a distance of 5 mm or
less are not detected by the lawn mower and are passed
max. 8 cm
over.
• Avoid creating corners with a 90° angle. Instead, divide them
into two 45° angles (side a ≤ 20 cm).
max. 2 cm
45°
• The lawn mower is able to detect and avoid stationary and
fi xed obstacles higher than 10 cm after contact (e.g. walls,
garden furniture, etc.). Protect sensitive obstacles (e.g. fl ower-
beds) on the lawn area with the boundary wire (11).
at least 30 cm (11.8 inches)
• Keep a distance of at least 1 m between bordered obstacles.
Border obstacles that do not meet this minimum distance as a
single obstacle.
Course for laying line of boundary wire
at least 1 m (39.37 inches)
• Never cross over the boundary wire. This can lead to faults
and failures in the lawn mower's operation.
Trees
The lawn mower detects trees as a normal obstacle. However,
protruding roots may damage the underside/blades (20).
We recommend using the boundary wire (11) to also border
trees.
90°
a
45°
GB