Step 8
Connecting APsystems microinverters to the grid
a. Please install bi-polar circuit breakers with the appropriate rated current or according to local regulations.
These circuit breakers are mandatory for grid connection.
b. Installation of leakage current breakers or AFCI/GFCI breakers is not recommended.
Step 9
AC extension cable
When an AC extension cable is required, users can either connect the AC bus cable and AC extension
cable within a junction box or use a pair of male/female AC connectors provided by APsystems as optional
accessories.
Step 10
Completing the APsystems installation map
a. Each APsystems Microinverter comes with 2 removable serial number labels.
b. Complete the installation map by affixing the ID label of each microinverter at the appropriate location.
c. The second serial number label can be adhered to the solar module frame. This label will assist in later
confirmation of the microinverter's position without the need to dismantle the PV module.
NOTE:
①. The arrangement of the microinverters' serial numbers in the installation map is designed for standard
installations.
②. The Installation Map can be found in the appendix on the last page of this manual.
③. When configuring the ECU, use the ECU_APP (accessible through the EMA Manager) to scan the serial
numbers on the map (refer to the ECU instruction manual for further details).
We, ALTENERGY POWER SYSTEM INC.
Of
Building 2, No. 522, Yatai Road, Nanhu District, Jiaxing City, Zhejiang 314050, China declare under our sole responsibility that the product
Product Description: Grid-tied Microinverter
Model No.: QT2, QT2-EU
to which this declaration relates, is conformity with the following standards and/or other normative documents.
Safety
Health
EMC
Radio
We hereby declare that all essential radio test suites have been carried out and that the above named product is conformity to all the essential requirements of
directive 2014/53/EU (RED).
Title: Director
Address: Jiaxing, China
Date: 2023/12/23
Zigbee Frequency Range:2405MHz - 2480MHz
Zigbee Maximum Power (EIRP):9.85 dBm
EU DECLARATION OF CONFORMITY
(No. 20231219)
EN 55011:2016/A2:2021; EN 62920:2017+A1:2021; EN IEC 61000-6-1:2019; EN IEC 61000-6-2:2019
EN IEC 61000-6-3:2021; EN IEC 61000-6-4:2019; EN IEC 61000-3-2:2019+A1:2021
EN 61000-3-3:2013+A1:2019; ETSI EN 301 489-1 V2.2.3(2019-11); EN 301 489-17 V3.2.4(2020-09)
Importer: Altenergy Power System Europe B.V
Address: Karspeldreef 8, 1101 CJ, Amsterdam, The Netherlands
Email: info.emea@apsystems.com
Manufacturer: Altenergy Power System Inc.
Address: Building 2, No.522, Yatai Road, Nanhu District, Jiaxing City, Zhejiang 314050, China
Bus Cable End Cap
EN 62109-1:2010; EN62109-2:2011
EN 62311:2020
ETSI EN 300 328 V2.2.2(2019-07)
3
METER
L1
L2
L3
N
PE
OR
Male/Female AC Connectors AC Junction Box
AC Extension Cable