Descargar Imprimir esta página

Dacor Pro DOP48 960 D Serie Manual De Instalación página 23

Estufa de combustible dual

Publicidad

Idiomas disponibles

Idiomas disponibles

Installing a 4-wire conduit
Aluminum building wire may be used but it must be rated for the correct
amperage and voltage to make the connection. Connect wires according to this
Step 4 depending on the number of wires.
Wire used, location and enclosure of splices, etc., must conform to good wiring
practices and local codes.
Ground strap
Ground plate
Red
Black
White
Neutral
terminal
Wire
White
Red
tips
Black
Ground wire
(Green)
DG68-01554A-00_IM_DOP48T960DS, DOP48T963DS_DA_EN+MES+CFR.indb 23
DG68-01554A-00_IM_DOP48T960DS, DOP48T963DS_DA_EN+MES+CFR.indb 23
1.
Loosen the 3 lower terminal screws
from the terminal block. Remove the
ground screw and ground plate and
retain them.
2.
Cut and discard the ground strap. Do
not discard any screws.
3.
Insert the ground bare wire tip between
the range frame and the ground plate
(removed earlier) and secure it in
place with the ground screw (removed
earlier).
4.
Insert the bare wire (white/neutral)
tip through the bottom center of the
terminal block opening.
5.
Insert the two side bare wire tips into
the lower left and the lower right
terminal block openings.
6.
Tighten the screws until the wire is
rmly secured (35 to 50 inch-lbs.). Do
not over-tighten the screws since it
could damage the wires.
7.
Go to Step 6 and proceed with the
installation.
Step 6. Replacing the access cover
Replace the access cover on the range back. To replace the wire cover, insert
double projections in the pockets located below the opening and tighten the screw.
English 23
2023-07-05 오후 2:19:25
2023-07-05 오후 2:19:25

Publicidad

loading

Este manual también es adecuado para:

Pro dop48 963 d seriePro dop48t963ds