Descargar Imprimir esta página

Dacor Pro DOP48 960 D Serie Manual De Instalación página 30

Estufa de combustible dual

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation instructions
Checking the ame quality:
All combustion ames need to be visually checked to determine their ame
quality.
Step 14. Final installation checklist
You have just completed installing your range. Make sure all controls are in the Off
position and the ow of ventilation air to the range is unobstructed. The following
is a checklist to con rm your range is safely installed and ready for operation.
Gas line has been properly connected to the range. The gas has been turned
on. All connections have been checked for leaks.
Range is plugged into the properly grounded electrical receptacle.
Approved anti-tip bracket is properly installed and engaged with the range.
Range is leveled and is rmly sitting on a solid, level oor.
All burners have been tested for proper operation.
30 English
DG68-01554A-00_IM_DOP48T960DS, DOP48T963DS_DA_EN+MES+CFR.indb 30
DG68-01554A-00_IM_DOP48T960DS, DOP48T963DS_DA_EN+MES+CFR.indb 30
1.
Prevailing soft blue ames—Normal for
natural gas operation.
2.
Yellow tips on outer cones—Normal for
LP gas operation.
3.
Yellow ames—Abnormal for any gas
operation; call for service.
NOTE
If burner ame looks like 3, the range
should not be used until it is serviced. Call
Dacor for service. Normal burner ames
shall look like 1 or 2, depending on the gas
type you use.
To adjust ame low setting
Identify which burner is exhibiting too high or too low simmer ame size, adjust
as necessary by following steps below:
1.
Simmer Set
Screw
Small
2.
Screwdriver
3.
Valve Stem
WARNING
1.
Do not completely remove the valve set screw from the valve stem. The valve
set screw is an integral part of the gas valve assembly. Removing the valve
set screw will cause gas to leak.
2.
After adjusting the valve set screw, inspect the assembly for gas leaks.
Rotate a knob to Lo position and
remove the knob from the valve stem
while the ame is lit.
Carefully push the screw driver into
the stem of the valve, until it hits
the simmer set screw. Make sure the
screwdriver athead is seated into the
set screw groove.
Rotate valve set screw clockwise to
decrease Lo setting ame output, or
rotate set screw counter clockwise to
increase Lo setting ame output.
2023-07-05 오후 2:19:28
2023-07-05 오후 2:19:28

Publicidad

loading

Este manual también es adecuado para:

Pro dop48 963 d seriePro dop48t963ds