Panasonic RR-XS450 Instrucciones De Funcionamiento página 80

Tabla de contenido

Publicidad

Troubleshooting guide
Symptom
Recording
Sound is recorded in a
recording mode other than the
set recording mode.
Recorded sound is too loud or
too low.
The level meter does not move
during recording. The recorded
file produces no sound.
Playing
No sound from the speaker.
Cannot hear any sound.
A file in the MIC_A to MIC_D,
LINE or RECYCLE folder cannot
be played.
80
80
• Did you change the microphone position before recording? When the direct
scene setting is set to ON, changing the microphone position will change the
recording mode to the set recording mode. (➜ page 23)
• Is the recording level adjustment set to manual? (➜ page 27) If so, set the
proper recording level (➜ page 28) or set the recording level adjustment
setting to AUTO.
• Switch the microphone sensitivity. (➜ page 26)
• Is the recording level adjustment set to "MANUAL" and is the recording level
set to "0"? Adjust the recording level. (➜ page 28)
• There is no sound when you have connected earphones. (➜ page 18)
• Adjust the sound volume. (➜ page 17)
• The file name was changed. Only files named according to the file naming
rules can be played in folder MIC_A through MIC_D, LINE or RECYCLE.
Even if file names are not changed, if some file numbers overlaps in the
folder, those files cannot be played. (➜ page 68) Playback is possible if they
are transferred to the MUSIC (M) folder. (➜ page 71)
• The transfer destination is wrong. If the file transferred from the computer is
stored in the recording folder, it cannot be played back on this unit. Transfer
the file to the MUSIC (M) folder. (➜ page 71)
Checkpoints

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rr-xs420