Taking Out Of Operation And Cleaning - Titan Control Max 1900 Pro Skid Instrucciones De Uso

Ocultar thumbs Ver también para Control Max 1900 Pro Skid:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 77
GB

Taking Out of Operation and Cleaning

Proper cleaning is the prerequisite for problem-free operation of the paint application device. No warranty claims are accepted
in case of improper or no cleaning.
Do not use lammable materials / cellulose thinner for cleaning purposes.
Danger
Always clean the device as soon as you have inished operation.
i
Dried-on coating substance makes cleaning more diicult.
1. Perform Pressure Relief Procedure.
2. Secure the spray gun.
3. Remove the nozzle holder from the spray gun. (Fig. 19)
4. Put the suction hose and return low pipe into a container full of water or suitable cleaning solution.
5. Turn the switch to the SPRAY position and set maximum pressure.
6. Hold the spray gun on the edge of the paint container. (Fig. 20)
Ground gun with a metal container if lushing with solvent.
Danger
7. Unlock the spray gun and pull the trigger to pump the excess paint out of the system into the paint container. Release the trigger again as
soon as the cleaning agent comes out.
8. Turn the switch into the PRIME position (vertical).
9. Hold the spray gun on the edge of the cleaning container.
10. Pull the trigger and hold it until only clear liquid comes out.
11. Switch the device of and remove the power plug.
12. Turn the switch into the PRIME position (vertical).
13. Pull the trigger to relieve the pressure.
14. Secure the spray gun.
15. Separate the spray gun from the paint hose using wrenches (13).
If the HEA ilter set is being used, remove it and clean it in accordance with the information in the chapter entitled
i
"HEA Filter Set".
16. Remove the nozzle (1), plain washer (2) and the mounting (3) from the nozzle holder (4) and clean all parts thoroughly.
(Fig.21)
17. Replace the mounting and the plain washer in the nozzle holder.
Screw the nozzle holder onto the gun.
18. Detach the suction hose from the basic unit.
19. Disconnect the return line.
20. Wipe of the exteriors of both hoses.
21. Carefully remove the ilter disc (1) from the suction ilter. (Fig. 22)
22. Clean the ilter disk thoroughly under running water.
23. Remove the high pressure hose from the basic unit with a wrench (17).
24. Immerse the inlet valve in a container illed with conservation agent (e.g. household oil). (Fig. 23)
25. Insert the power plug.
26. Hold a cloth in front of the hose connection and switch the device on for approx. 5 seconds. (Fig. 24)
This procedure preserves the pump.
2 4
Control Max 1900 Pro Skid

Publicidad

Tabla de contenido
loading

Tabla de contenido