HYTROL Integration Partner. Electric divert Switch Removal Procedure ..11 2. Give Conveyor model Number and Serial Number or HYTROL factory Order Number. Electric Switch Homing Procedure ...11 3.
In an effort to reduce the possibility of injury to personnel working emergency exits if a suitable warning indicates low headroom. around HYTROL conveying equipment, safety labels are placed at various points on the equipment to alert them of potential hazards.
(SOPORTE ANGULAR) (SOPORTE INDUCCION) (SOPORTE MOTRIZ) of installation. CONVEYOR CONVEYOR FLOW ITEM ITEM HYTROL CONVEYOR CO. INC. HYTROL CONVEYOR CO. INC. JONESBORO, AR JONESBORO, AR (FLUJO) "MATCH-MARK NUMBERS" (ETIQUETAS DE SECUENCIA DE ARMADO) • Conveyor Set-Up FIGURE 4B 1. mark a chalk line on floor to locate center of the conveyor.
FIGURE 5A FIGURE 5B LINE TO VALVE INTERMEDIATE (lInea a ValVUla) SWITCHES 1/2" TO 3/8" REDUCER (InterrUptOres (redUCtOr de 1/2" a 3/8") END SWITCH 3/8" FEMALE TO 3/8" MALE IntermedIOs) QUICK CONNECT FITTING (InterrUptOr PLUG INTO VALVE eXtremO) (Hembra de 3/8" a maCHO de 3/8" PRESSURE SWITCH de rapIda COneXIOn a ValVUla) PRESET AT 48 PSI...
Hytrol, the Hytrol Integration Partner or a third party. TO SOLENOId Hytrol has built into the sorter some of the controls necessary to operate the "Y" CONNECTOR divert switches, eliminating the need to control this function externally. Other 032.21124...
Página 7
In addition to the control components supplied with the ProSort sorter, there are be shut down until the cause of the pressure drop has been found and remedied. several components that must be supplied by the system control provider. Hytrol The pressure switch provides a contact-type output which closes at pressures at recommends the following control components be used to protect the sorter from or above about 48 PSI and opens below that air pressure.
3 1/2” FIGURE 8A MOUNTING ANGLE MISSING BEARING 2.355” ANGULO DE MONTAJE DETECTION BLOCK BLOQUE DE DETECCIÓN DE RODAMIENTO FALTANTE FEMALE CABLE EXTENSION FEMALE CABLE EXTENSION CABLE HEMBRA DE EXTENCIÓN CABLE HEMBRA DE EXTENCIÓN Brown (Café) Not Used (No Se Usa) White (Blanco) Not Used (No Se Usa) Blue (Azul) Common (Común)
• Install Guard Rails at FIGURE 10A Divert Locations If guard rails are to be installed on the spurs and/or the spur side of the sorter, care should be taken to insure that the guard rails do not interfere in any way with the boxes being diverted.
• Electric Divert Switch Removal Procedure FIGURE 11A REMOVE BOLTS (RETIRE TORNILLOS) The ProSort is designed for easy removal of the divert switch assembly for maintenance or replacement. In order to remove the electric switch assembly follow the following steps. 1.
• Model ProSort 421 Parts Drawing Dibujo de Partes del Modelo ProSort 421 Catenary Divert and Drive Section (Catenaria de desviación y sección motriz) 46 13 55 54...
• Model ProSort 421 Parts Drawing Dibujo de Partes del Modelo ProSort 421 Intermediate and Return Divert Section (secciones de desviación Intermedia y de retorno) NOTE: Place chain covers so that no seams are located within the spur/ diverting area. NOTA: Coloque las cubiertas de cadena para que no haya empalmes en el área de...
• Model ProSort 421 Parts Drawing Dibujo de Partes del Modelo ProSort 421 Induction Unit (Unidad de Inducción) FLOW/FLUJO 146 166 142 164 148 140 154 153 169 168 • Model ProSort 421 Parts List Lista de Partes del Modelo ProSort 421 REf NO.
Página 16
• Model ProSort 421 Parts List Lista de Partes del Modelo ProSort 421 REf NO. PART NO. dESCRIPTION REf NO. PART NO. dESCRIPTION 040.701 7/8-9 x 6" Lg Hex Head Bolt for KT97 Gearmotor 041.9069 Speed Grip Nut Retainer - 1/4-20 042.700 7/8-9 x 2-1/2"...
Página 17
• Model ProSort 421 Parts List Lista de Partes del Modelo ProSort 421 REf NO. PART NO. dESCRIPTION REf NO. PART NO. dESCRIPTION 010.203 1-7/16” Bore 4-Bolt Bearing 0265-252216 31-1/2 in Long Pan 010.2045 1-11/16" Bore 4-Bolt Bearing Bolt in Pan 36” OAW 108.044327 44PTH8 - 35Sd x 1-11/16"...
• Model ProSort 431 Parts Drawing Dibujo de Partes del Modelo ProSort 431 Catenary Divert and Drive Section (Catenaria de desviación y sección motriz) 29 15 47 7...
• Model ProSort 431 Parts Drawing Dibujo de Partes del Modelo ProSort 431 Intermediate and Return Divert Section (secciones de desviación Intermedia y de retorno)
• Model ProSort 431 Parts Drawing Dibujo de Partes del Modelo ProSort 431 Induction Unit (Unidad de Inducción) FLOW • Model ProSort 431 Parts List Lista de Partes del Modelo ProSort 431 REf NO. PART NO. dESCRIPTION REf NO. PART NO. dESCRIPTION WA-015050-L drive Side Chnl Weldment - LH...
Página 22
• Model ProSort 431 Parts List Lista de Partes del Modelo ProSort 431 REf NO. PART NO. dESCRIPTION REf NO. PART NO. dESCRIPTION Photoeye - Retro-Reflective, 10-40 VDC 033.2130 PT-115582-R Chain Wearstrip - RH Reflector - 3.30" Dia. 032.2185 PT-053735 Chain Guide mounting Angle - Tail 042.1019 #10-24 x 3/4"...
Página 23
• Model ProSort 431 Parts List Lista de Partes del Modelo ProSort 431 REf NO. PART NO. dESCRIPTION REf NO. PART NO. dESCRIPTION 0265-174120 21-3/4 in. Long Pan 0265-168264 21 in. Long Pan 0265-180120 22-1/2 in. Long Pan 0265-172264 21-1/2 in. Long Pan 0265-186120 23-1/4 in.
• Pneumatic Divert Switch Assembly Parts Drawing Dibujo de las Partes del Ensamble Interruptor Desviador Neumatico REf NO. PART NO. dESCRIPTION Switch Channel PT-051011 Left Hand PT-051456 Right Hand PT-051013 Switch mounting Angle Switch Plate Weldment WA-014806 Left Hand WA-014807 Right Hand Prox Switch mounting Angle PT-051422...
CONVEYOR CONVEYOR FLOW ITEM ITEM área de instalación. HYTROL CONVEYOR CO. INC. HYTROL CONVEYOR CO. INC. JONESBORO, AR JONESBORO, AR (FLUJO) "MATCH-MARK NUMBERS" (ETIQUETAS DE SECUENCIA DE ARMADO) • Montaje 1. marque con tiza una línea en el suelo para ubicar el centro del transportador.
Página 28
CHAIN GUIDES MUST BE FIGURE 28A FIGURE 28B EVEN AT JOINT (las gUIas de Cadena WEARSTRIP CHAIN GUIDE deben ser UnIFOrmes (gUIa de Cadena) en la UnIOn) THREADED RODS (VARILLAS DE ROSCA) SECTION JOINT BEARING PROFILE (UnIOn de seCCIOnes) (perFIl del rOdamIentO) CONVEYOR CHANNEL (Canal del transpOrtadOr)
únicos y adecuados para ese sistema. Estos controles son usualmente es decir, si se presenta una pérdida de corriente o una falla en el mismo dispositivo, proporcionados por el distribuidor Hytrol, el usuario o por un tercero. esto no debe representar ningún peligro.
Página 30
Hytrol, el cual tiene la “inteligencia” para controlar la regulación del tiempo del de un esfuerzo en caso de un arranque repentino. interruptor. el prox se conecta al cable Y. Ver figura 30a: 2.
Página 31
FOTO CELDA largo de toda la longitud del sorter. las foto celdas son componentes comunes en los controles del sistema. Hytrol 2. el interruptor de seguridad de los rodillos de transición es usado para detectar recomienda que las foto celdas sean instaladas en los siguientes lugares para que cuando los rodillos de transición en la zona de descarga están “levantados”.
3 1/2” FIGURE 32A MOUNTING ANGLE MISSING BEARING 2.355” ANGULO DE MONTAJE DETECTION BLOCK BLOQUE DE DETECCIÓN DE RODAMIENTO FALTANTE FEMALE CABLE EXTENSION FEMALE CABLE EXTENSION CABLE HEMBRA DE EXTENCIÓN CABLE HEMBRA DE EXTENCIÓN Brown (Café) Not Used (No Se Usa) White (Blanco) Not Used (No Se Usa) Blue (Azul) Common (Común)
• Lista del Interruptor Desviador Eléctrico FIGURE 33A SWITCH BLOCK nOta: todos los desviadores eléctricos servomotores están asignados a las unidades (NON-DIVERT POSITION) DIVERT BLOCK asociadas en la fábrica. Conectar los motores a la unidad incorrecta puede tener un [BLOQUE INTERRUPTOR (BLOQUE DESVIADOR) (POSICION NO DESVIADORA)] efecto negativo en la operación desviadora y podría provocar daño físico al clasificador.
• Instalando las Guardas FIGURE 34A en Puntos Desviadores si las guardas laterales se van a instalar en las espuelas y/o en el lado de la espuela del sorter, debe tenerse cuidado de que las guardas no interfieran en de ninguna manera con el producto que esta siendo desviado.
• Procedimiento de Desarmado del Interruptor Desviador Eléctrico El ProSort está diseñado para quitarlo fácilmente del ensamble del interruptor desviador, para mantenimiento o FIGURE 35A para reemplazo. Para desarmar el ensamble del interruptor desviador siga los pasos siguientes. 1. Desconecte toda fuente de alimentación eléctrica que vaya hacia el tablero conectado al desviador que REMOVE BOLTS (RETIRE TORNILLOS) necesita quitarse. Esto incluye apagar el interruptor al frente del tablero poniéndolo en la posición OFF, así...
Angulos Desviadores - revise si hay areas dobladas. revise si la banda de proteccion esta floja o extraviada. ( 8 7 0 ) 9 3 5 . 3 7 0 0 2020 HYTROL STREET W W W . H Y T R O L . C O M JONESBORO, ARKANSAS 72401...