6. Dip Switch

DIP Switch settings for Single Loop (LDD1)
5 6
LOOP
4
7
3
8
RELAY 1
2
9
1
10
RELAY 2
SENSITIVITY
Selection
1
mode
2
Channel
selection
3
4
Turn-on delay
5
ASB
6
Failure mode
7
Output mode
8
Time
9
Entry / Exit
10
Output mode
11
Time
12
Entry / Exit
DIP SWITCH 1 - Frequency mode selection
The Loop Detector operates on one out of four channels. If the Loop Detector is located near sources
of electrical or magnetic disturbances, e.g. from other Loop Detectors, some channels can be more
advantageous to use than others. Two Loop Detectors placed in close proximity of each other should
use different channels to avoid crosstalk between the loops.
• When DIP SWITCH 1 is set to ON, the user manually selects which channel is used by setting DIP
switch 2 and 3.
ON
Frequency settings
Automatic channel selection
DIP switch 2 and 3 are not used in
automatic channel selection
General settings
Delay OFF
ASB OFF
Fail safe
Relay 1 settings
Pulse mode
0.1 sec pulse
0.5 sec pulse
Vehicle entry
Relay 2 settings
Pulse mode
0.1 sec pulse
0.5 sec pulse
Vehicle entry
1
Infinite
Vehicle exit
Infinite
Vehicle exit
Rev.00 - 03.2019 | LDD1/LDD2 Single and Dual Loop Detector | © 2019 | CARLO GAVAZZI Industri
Manual channel selection
2
3
Delay 2.0 sec
ASB ON
Fail secure
Presence mode
60 min
10 min
Presence mode
60 min
10 min
4
1 min
1 min