TPD
Defined for Amate Audio loudspeakers. Provide extra EQ and limiter
settings
JK26A+2JK12W).
The user can only modify the input parameters. Cannot be overwritten.
Preset 31 to 100: User presets (Empty).
Free slots to store modifications made on read-only presets.
Only Admin users can load an empty preset.
No.
Type
Read-
Only
1
Generic Yes
2
Generic Yes
3
Generic Yes
4
Generic Yes
5
Generic Yes
6
Generic Yes
7
Generic Yes
8
Generic Yes
9
Generic Yes
10
Generic Yes
11-
Amate
Yes
30
31-
User
No
100
Table 3. Configuration of the in-built presets
WARNING: Presets marked as Read-Only can be modified, but not
overwritten. To save a modified factory preset, a User slot (in the
position 31 to 100) must be used.
WARNING: Make sure that you select a preset that matches the load
impedance of the subwoofers. If the total load of the channel is 4 Ohm
select a "4 Ohm load" preset. If the load is 8Ohm, select "8 Ohm load".
Default presets are optimized for a 4 Ohm load.
5.3 System Optimization
The built-in presets of the TPD have been adjusted to obtain the maximum dynamic
range from the amplifier. It is recommended to control the output power by regulating
11
to
improve
the
Name
Xo100+SW4Ohms
Xo100+SW8Ohms
Xo110+SW4Ohms
Xo110+SW8Ohms
Xo120+SW4Ohms
Xo120+SW8Ohms
Xo80+SW4Ohms
Xo80+SW8Ohms
Xo90+SW4Ohms
Xo90+SW8Ohms
Specific presets for Amate Audio loudspeakers.
The model list depends on the firmware version
Please refer to the list enclosed with this manual
Empty
performance
of
Out SW
Out L
(AUX1)
(AUX2)
LPF 100 Hz
HPF 100 Hz
4 ohm Load
LPF 100 Hz
HPF 100 Hz
8 ohm Load
LPF 110 Hz
HPF 110 Hz
4 ohm Load
LPF 110 Hz
HPF 110 Hz
8 ohm Load
LPF 120 Hz
HPF 120 Hz
4 ohm Load
LPF 120 Hz
HPF 120 Hz
8 ohm Load
LPF 80 Hz
HPF 80 Hz
4 ohm Load
LPF 80 Hz
HPF 80 Hz
8 ohm Load
LPF 90 Hz
HPF 90 Hz
4 ohm Load
LPF 90 Hz
HPF 90 Hz
8 ohm Load
Jul 2016
the
loudspeaker
Out R
(AUX3)
HPF 100 Hz
HPF 100 Hz
HPF 110 Hz
HPF 110 Hz
HPF 120 Hz
HPF 120 Hz
HPF 80 Hz
HPF 80 Hz
HPF 90 Hz
HPF 90 Hz
Amate Audio
(i.e.