2.5.2 Especificaciones de Agencia - Instalación FM/CSA F
Ui (Vmax) = 17.5V
Ii (Imax) = 380 mA
Pi = 5.32 W
Ci = 440pF
Li = 2.7µH
Leakage current < 50µA
Ui (Vmax) = 17.5V
Ii (Imax) = 380 mA
Pi = 5.32 W
Ci = 440pF
Li = 2.7µH
Leakage current < 50µA
Any FM/CSA Approved
Intrinsically Safe
Associated Apparatus with
Parameters suitable for the
FISCO Concept.
Ui (Vmax) = 24V
Ii (Imax) = 280mA
Pi = 1.93W
or
Any approved termination on with
R = 90 ... 100
C = 0 ... 2.2µF
SP-ORI-650 Transmisor Magnetostrictivo Jupiter
R
C
Modelo JM4
®
fieldbus
oundation
Any FM Approved
Intrinsically Safe
Associated Apparatus with Entity
Parameters suitable for the
FISCO Concept.
:
FOR PROPER INSTALLATION REFERENCE ALL
APPLICABLE NOTES FROM PAGE 2 - 99-5074-001
IS
TM
51