Weq CFW700 Serie Manual Del Usuario página 30

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

NOTE!
It is necessary to set the password at P0000 for parameter modification.
Otherwise the parameters contents can only be viewed.
The default password for P0000 is 5. It is possible to change the password at
P0200. Refer to the CFW700 programming manual.
Motor rotation
Menu (parameters
group selection) –
only one parameter
group is shown at
each time.
Parameter groups available at the Menu:
PARAM: all parameters.
READ: only the reading parameters.
MODIF: only the parameters changed compared to the factory default.
BASIC: basic application parameters.
MOTOR: parameters related to motor data control.
I/O: parameters related to the digital and analog inputs/outputs.
NET: parameters related to the communication protocol.
HMI: parameters for the keypad configuration.
SPLC: parameters related to the SoftPLC function.
STARTUP: parameters for the Oriented Start-up.
Local/Remote
(commands and
references source)
Main display
Figure 4.2: Display sections
Keypad (HMI) and Basic Programming
Inverter status
Secondary display
Variable unit
(shows the value of
the main display)
Variable monitoring
bar graph
CFW700 | 25

Publicidad

Tabla de contenido
loading

Tabla de contenido