Operation
5.5 Special functions
In this chapter all functions that may be accessed by
the operator are described. A function is a "mode" that
is not required to balance a wheel properly.
5.5.1 Weight mode on start up
To set the default weight mode after power up to HWM1
instead of NORMAL:
• Keep the return key pressed down.
• Plug the power cable into the power outlet.
The unit will do a self check.
All indicators and displays will be on during several
seconds, thus enabling the operator to check if
everything is functioning.
• Release the return key after a short beep is heard.
The default weight mode will be HWM1.
The order in which the weight modes are accessed
is not influenced.
The unit is now ready to receive input.
Operator's Manual
Funcionamiento
5.5
Funciones especiales
En este capítulo se describen todas las funciones a las
que el operador puede acceder . Una función es un
"modo" que no requiere que la rueda sea equilibrada
adecuadamente.
5.5.1 Tipo de rueda al arranque
Para fijar el tipo de rueda por defecto después de
arrancar de NORMAL a HWM1:
• Mantenga la tecla de retorno pulsada.
• Enchufe el cable en la toma de corriente.
La unidad hará una auto-comprobación.
Todos los indicadores y pantallas estarán encendidos
durante varios segundos para permitir que el operador
compruebe si todo está funcionando.
• Suelte la tecla de retorno después de oir un bip
corto.
El tipo de rueda por defecto será HWM1.
El orden de acceso a los tipos de ruedas no influye.
La unidad está lista para recibir los datos.
b 9005
Manual de Operador
b 9005
59