1.11.3. Back panels
the back is completed.
Warning: when the ash box or the grill, are settled, the central panel is lower, which is
perfectly normal
1.11.4. Foot Heat-resistant panel
as fig 25-26 indicate.
1.11.5. Diagram for heat-resistant panel
1.12. Deflexed Panel assembly
and behind the back at the top of foot heat-resistant panel.
1.13. Cleaning and maintenance. It is highly recommended an accessible zone for the leaning
of the apparatus, smoke chamber and smokestack.
USER'S GUIDE
2 .
ALL LOCAL REGULATIONS, INCLUDING THE ONES ACCORDING TO THE NATIONAL OR
EUROPEAN NORMS MUST BE ACCOMPLISHED WHEN PROCEEDING TO INSTALL THE
FIREPLACE.
Warning: Do not operate or handle any part when the fireplace is working unless using
the exothermic glove.
2.1. Using for the first time. For early on, and for a reasonable time, the fuel load should not
exceed 50% C.M.A. (Maximum fuel load authorised by the manufacturer).
2.2. Fire control. To obtain the correct performance, do as it follows:
Primary register
2.2.1. Mono-command register
fire and regulate fire intensity, when sliding it from sides, it activates the primary register. The
other way around, it activates the secondary one. The more closed, the dirtier.
ATTENTION:
The positions indicated are according to technical characteristics table, in any case
these positions must be adapt according to the flue depression and fuel quality.
2.3. Security distances. Furniture, objects and the rest of flammable or fragile things (textile,
electronic devices, wood, wall paper, glass, chalk etc) must be, at least, at a distance of 1000
mm away from the fireplace and outer walls of the chimney. The hot air outlets distance must
also be taken into account in a distance of 250 mm.
2.4. Fire types. This apparatus is an on and off fire. The smoke chamber must be closed except
when being loaded, to avoid any smoke out fuel debris. It is convenient when loading the
fireplace, to avoid any leak or smoke escape.
2.5. Authorized fuel. The apparatus must not be used as an incinerating device. Only logs of
natural wood are recommended, humidity within 12 and 20 % . It is highly recommended the
use of at least 2 year-old logs. The use of other types of fuel is forbidden, as well as any liquid
used to light barbecue fires. Their maximum length might not be longer than 450 mm.
The procedures is the same, start with the lateral pieces till
(20-21-22-23-24).
(25-26).
(27-28).
45%
open
It is situated off the outdoor frames It is used to light the
(29).
To secure the panels, use 2 "L" plates and put them
.
Components
1Ud. Units of 110x400x30 panels (A)
2Ud. Units of 200x400x30 panels (B)
1Ud. Units of 150x400x30 panels (C)
4Uds. Units of 200x500x30 panels (D)
1Ud. Units of 80x500x30 panels (E)
1Ud. Units of 150x500x30 panels (F)
Collocation:
1. 110x400x30 panel
2. 200x400x30 panel
3. 200x400x30 panel
4. 200x500x30 panel (side)
5. 80x500x30 panel
6. 200x500x30 panel (back)
7. 150x500x30 panel
It must be placed at the top part of the lids in each side
Secondary register 5%
open
Página 16 de 25