4 .
MARKED
The marking label is behind of the guillotine door support in
the left side (to access it you have to remove the frame).This
tag contains the technical data and the Nº O.F. (this number
is also available on the warranty. This number is essential to
order replacement parts.)
Below is the table of technical characteristics:
MANUFACTURAS ROCAL SA
Raval Sant Antoni, Nº 2
08540 Centelles – BCN (Spain)
T: + 34 93 8812451
F: + 34 93 8810631
e-mail:
web: www.rocal.es
G 30 LD - LI (M1612-M1613)
STAINLESS STEEL CASTING AND FIT IN FIREPLACE WITH GUILLOTINE
(RIGHT – LEFT)
SIDE OPENING
Nominal efficiency:
Output :
CO concentration at an average of 13% O2 :
Temperature of fumes:
Functioning:
Pipe :
Distances minimum adjacent combustible materials:
-
side wall :
-
side wall (glass open side):
-
back wall:
-
floor:
-
front:
Use only authorised fuel:
READ AND FOLLOW AN OPERATING INSTRUCTIONS
TEST REFERENCE Nº 08/32310398
Organism Notified Nº 370 - LGAI Technological Center, SA
Tests have been taken under the regulations of norma UNE-EN 13229:2002-A1:2003-
2002/A2:2005-2002/AC:2006-2002/A2:2005/AC:2007 'Fit in devices and mechanisms,
including fireplaces which may use solid fuel – Requirements and methods for test.
THE GUARANTEE IS SUBJECTED TO THE ACCOMPLISHMENT
OF ALL DESCRIBED ABOVE OTHERWISE THE GUARANTEE SHALL BE NULL AND VOID.
man.rocal@rocal.es
08
UNE-EN 13229:2002/A1:2003
UNE-EN 13229:2002/A2:2005
UNE-EN 13229:2002/AC:2006
UNE-EN 13229:2002/A2:2005/AC:2007
72%
11 Kw
0,22%
340ºC
On and off
NOT share
150 mm
1000 mm
150 mm
200 mm
1000 mm
Logs of natural