Rocal G 30 LD-LI Manual De Caracteristicas, Instalacion Y Funcionamiento página 18

Publicidad

Idiomas disponibles

Idiomas disponibles

3 .
DETECTION OF MALFUNCTION
The table below shows the possible malfunctions, what brought them about and the solutions to
follow:
MALFUNCTION
1-
Smoke
mislead
insufficient air intake.
2- Glass (too dirty)
3 - Little heating
4-
Smoke
going
through front door.
4-
Smoke
going
through front door.
((continue)
5- Malfunction of opening
mechanism.
6- Door moves itself.
Checking and replacing of installation, spare pieces as well as pipes, should be done by experts.
For more details, please contact the corresponding Rocal Department.
CAUSE
or
Inadequate pipe.
Insufficient air for combustion
Inadequate pipe.
Inadequate fuel.
Excessively closed smokestack registers
Inadequate fuel.
Insufficient load.
out
First lit.
Flammable or combustible elements inside
the fireplace or around.
out
Crack in the flue.
Blockage of the mechanism.
Misadjusted counterweight.
SOLUTION
Check pipe:
-connection
-diameter
-leaks
-insufficient length
-outlet
-blockage
Check the flue draught entry
Check pipe.
Use authorized fuel.
Graduate opening.
Authorized fuel
Revise fireplace room, seal the
possible inlet.
Wait for the polymerization process
(more than one lit).
Check
insulation
material
fibre,
igneous
wood
elements) , possibly replace them.
Check for cracks and call dealer.
Free the door and close it some
centimetres.
Remove front frame and add or
subtract weight
(see the paragraph 1.3)
Página 18 de 25
(glass
or
other

Publicidad

loading

Este manual también es adecuado para:

G 45 ldG 45 li