5 – USE OF MACHINE
5.1 Start up of machine and loading of
water inside boiler
Open the water shut-off valve.
Bring the lever of the omnipolar switch belonging
to the electric system on ON.
When the switch (fig. 01-01A; pos 10) is brought
in position "1" (Red light (Fig. 01-01A; pos. 15)
turn on), the water is loaded inside the boiler; af-
ter 120 seconds of loading, the machine goes in
alarm status; bring the switch in "0" position and
repeat the operation by pressing the same switch
a few times, until the pump has completely loaded
the boiler and shuts off.
Once the minimum level has been reached, the
green light (Fig. 01-01A; pos 9) will turn on and
the switch (Fig. 01-01A, pos. 10) can be brought
in position "2" to enable the resistor and you will
have the orange light turns on (Fig. 01-01A, pos.
8).
Wait that the boiler's pressure gauge (Fig. 01-01A;
pos 11) indicates a pressure between 1 and 1.2
bar (0.1 – 0.12 MPa) prior to use the machine.
5.2 Heating
To make sure that the machine has reached the
right thermal balance between temperature and
pressure, when the boiler's gauge indicates a pres-
sure between 1 and 1.2 bar (0.1 – 0.12 MPa), press
the steam tap (Fig. 01-01A; pos 1) and exhaust the
steam 2 or 3 times in the discharge basin.
The green light (fig. 01-01A; pos 9), if turn off,
warns about the insufficient water level inside the
boiler.
The orange light (fig. 01-01A; pos 8), if turn on,
signals the enabling of the resistor.
Warning:
when the green light (fig. 01-01A; pos 9) is off, a
safety device does not allow the machine to work;
contact the technical assistance service.
5.3 Preparation of coffee
Warnings:
BEZZERA B2013-C2013 Compact
MOD.
- Do not remove the filter holder when the device
is on: burning hazard.
- Do not touch directly the metal part of the filter
holder and group: burning hazard.
- The standard doses for the filters are 6/8 grams
for a dose and 12/14 grams for two doses.
1) Remove the filter holder from the supply group.
2) Load the filter holder with ground coffee, press
the coffee paying attention not to dirty the bor-
der of the filter holder.
3) Hook back the filter holder in its location.
4) Act on the coffee supply command, by pressing
one of the keys (Fig. 01-01A; pos. 3), based on
the dose to supply.
Press again the button (Fig. 01-01A; pos. 3) to stop
supply when the desired dose has been reached.
4) Act on the coffee supply command, by pressing
one of the keys (Fig. 06; pos. a - d), based on
the dose to supply.
To change the programming of doses, follow the
instructions indicated in paragraph 5.7 of this
booklet.
The machine is also conceived for continuous out-
put:
1) start the output by pressing the continuous out-
put key (Fig. 06; pos. f)
2) stop the output once the wanted quantity has
been reached, by pressing once again the con-
tinuous output key (Fig. 06; pos. f)
Warning: The machine is equipped with
an automatic safety device that stops
continuous output after the third con-
secutive litre.
5.4 Steam supply
1) To avoid refluxes of fluid inside the boiler, ex-
haust the steam by acting on the tap's knob (fig.
01-01A; pos. 1).
2) Introduce the steam nozzle (Fig. 01-01A; pos 4)
in the fluid container to heat up.
3) Press the steam key (Fig. 01-01A; pos 1). The
quantity of steam supplied is proportional to the
opening of the tap; the greater is the opening
33
PM Model