RS02
System set-up
4.1- Power supply line wiring
Inside the transformer compartment there is a terminal with a 2 AT protection fuse, connect the phase in the corresponding pole to the fuse.
4.2- Wiring for flashing light, courtesy light and gate/barrier movement warning light
N.B.: Do not change the motor output wiring (terminals 1 and 2) the parameter number 31 selects the direction of opening
Terminals
Description
1-2
Motor output
3-4
Courtesy light or second radio channel Output 12 V dc maximum load 65mA, can be programmed as a timed output (60 seconds) or
4-5
Warning light output
6-7
Accessories power supply output
8-9
Output for flashing light
Input description table:
The control unit is supplied with jumpered normally closed inputs (STOP, FOTO and STPA) remove the jumper from the input you are going to use.
CN2
10 11 12 13 14 15 16
Fuse 2 A L 250 V (Mains: 230 V, 240 V)
Fuse 4 A L 250 V (Mains: 110 V, 117 V, 125 V)
+
-
-
+
white
M
Electric
Power supply output for ac-
motor
cessories 12V dc 300mA
12 V dc 65 mA max
12 V dc 65 mA max
Courtesy light or sec-
gate/barrier move-
ond radio channel
ment warning light
Function
Output for controlling electric motor 12 V dc rated power 50 W
(terminal number 1 white, terminal number 2 brown)
second radio channel output (3 = GND / 4 = +12 V dc).
Output 12 V dc maximum load 65mA, flashes slowly when opening, on with stationary open
gate/barrier, flashing fast when closing and off with gate/barrier closed (4= +12 V dc / 5= GND).
Output 12 V dc maximum 300 mA for supplying the photocells and accessories
(6 = +12 Vdc, 7= GND)
Output 12 V dc maximum load 15 W for flashing light (8 = GND, 9 = + 12 V dc).
Terminal number
Description
10-13-18
Control inputs common (permanent GND)
Sequential control input, for
11
controlling the complete travel of the gate/barrier
Sequential control input, for
12
controlling the pedestrian travel of the gate/barrier
14
Input for stopping the gate/barrier
15
Photocell input, active during gate/barrier closing
Input for edges or internal photocell, active during gate/bar-
16
rier closing and opening
Opening limit switch input with parameter 31 OFF
17
Closing limit switch input with parameter 31 ON
Closing limit switch input with parameter 31 OFF
19
Opening limit switch input with parameter 31 ON
-
-
+
12 Vdc 15 W max
EN
Fig. 4
Fig. 5
Input type
-
Normally open
Normally open
Normally closed
Normally closed
Configurable: normally closed or
balanced at 8.2 K ohm
Normally closed
Normally closed
25