10 - Installing batteries
Insert the battery charging circuit in the battery card connector and connect the batteries to the circuit, with battery operation the speed of the motor is 15%
lower than the speed with mains power, the number of operations with the batteries depends on the number of photocells in the system and the length of
the gate/barrier.
11 - Troubleshooting
Problem
The automatic gate/barrier system does
not work
You cannot save the remote controls
The remote control does not work
You cannot enter travel programming
As soon as the gate/barrier starts it stops
and reverses
During slowdown, the gate/barrier stops
and reverses
Cause
No mains supply
Blown fuses
Control and safety inputs not working
Safety devices open
Batteries of the remote control discharged
Remote control not compatible with the first one saved
Reached memory saturation
Batteries of the remote control discharged
Safety devices open
Low acceleration on starting
Slowdown speed too low
EN
Solution
Check the power line switch
Replace the fuses with others of the same value
Check the diagnosis LEDS (STOP, STPA and
FOTO must be on)
Check the diagnosis LEDS (STOP, STPA and
FOTO must be on)
Replace the batteries.
The first saved remote control configures the control
panel to save only rolling-code remote controls or
only dip-switch remote controls.
Delete at least one remote control or add an external
receiver (maximum capacity 200 remote controls).
Replace the batteries
Check the diagnosis LEDS (STOP, STPA and
FOTO must be on)
Decrease the value of parameter 24
Check the encoder connector is inserted (during
gate/barrier movement the enc a and enc b LEDs
must be on)
Increase the value of (parameter 13 and 14) or de-
celeration too fast (parameter 25)
41