Operating Instructions - Miele PTD 701 AE RO Manual De Instrucciones

Ocultar thumbs Ver también para PTD 701 AE RO:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 63

Operating instructions

for PTD 701 AE RO, AE RO DOS / PTD 702 AE RO, AE RO DOS
(Machines with built-in reverse osmosis module)
Please observe the operating instructions carefully.
Also adhere to the quick guide and safety notes included with the machine.
1.
Description
(1)
PTD 701 AE RO, AE RO DOS
2.
Commissioning
Ensure that commissioning is carried out by an authorised Miele service technician or
your dealer.
The service technician will put your machine into service for the first time and, together with
Caution
you, will adjust the settings of the reverse osmosis module ( 3).
3.
Setting of the reverse osmosis module by the service technician
3.1 PerfectWater
The PerfectWater function ensures that RO water with a consistent quality is always available for rinsing. RO
water that does not have this quality is returned to the reverse osmosis module. The service technician can
set the quality of the RO water to three levels (good, better, best). The factory setting is "better".
3.2 WaterEco
Upon delivery, rinsing with RO water is activated for all washing programmes. If required, the service techni-
cian can activate the WaterEco function and assign the individual washing programmes different qualities of
water for the rinse cycle:
Water quality
Quality 1
RO water
Quality 2
Quality of the inlet water
INFO
To ensure that RO water is available immediately after changing from a washing programme using
quality 2 rinsing water to a washing programme using RO water, the machine boiler is rinsed.
TIP
All washing cycles using quality 2 rinsing water should be run together, as rinsing the boiler con-
sumes additional water and increases the time of the programme.
If the water hardness level exceeds 3 °dH (0.5 mmol/l) we recommend the use of a water softening unit to
improve the performance of the reversis osmosis module. Moreover, the machine may develop limescale
deposits if the WaterEco function is used frequently.
(1)
PTD 702 AE RO, AE RO DOS
Wash item
Glasses, cutlery, ...
Chinaware, trays, cooking utensils, ...
The reverse osmosis module (1) underneath
the machine produces RO water for rinsing.
RO water is water that has had most of its
salts and minerals extracted through the pro-
cess of reverse osmosis.
5
English

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ptd 701 ae ro dosPtd 702 ae roPtd 702 ae ro dos

Tabla de contenido