OPERATION MANUAL AND INSTRUCTIONS
ISTRUZIONI PER L'USO
STEP 2
- After STEP 1 has been completed, the station will proceed to STEP 2, "Cleaning", requiring the user to have started the car
with the gearshift in the parking ("P") or neutral ("N") position. The display will show the following:
- Start the car keeping the gearshift in "P" or "N" position, and quickly press the
circuit, filtering impurities, and then show the time remaining to the end of the operation. During cleaning, as the car has been
placed on a lift with raised wheels, all the gears – including the reverse gear – should be shifted a few times.
Cleaning must be performed with warm transmission oil.
- If the startup screen shows that the amount of solvent has been set to "0", the station will automatically skip STEP 1 and
immediately move on to STEP 2.
STEP 3
- When the set time has elapsed, the station will emit a few beeps, and STEP 3, "Emptying oil sump", will automatically start.
The display will show the following:
- As the station empties the oil sump, the display will show the amount discharged into the tank marked "OLD OIL" and
connected to the station through a black pipe. After the oil sump has been emptied, the station will automatically stop, and
emit a few beeps to indicate the end of the operation; the display will show the following:
During this step, the old oil sight glass should be looked at, and the station turned off if any air bubbles are
found in it.
- QUICKLY switch off the car. Press the
sump. The display will show the following:
- Then remove the oil sump, paying attention to any oil residues found in it. Clean both the oil sump and the magnets found in it;
replace the filter and the gearbox gasket. After these operations have been completed, press the
- If in the start-up screen both the amount of solvent and the duration of the cleaning cycle have been set to "0", the station will
automatically skip STEP 1 and STEP 2, and immediately move on to STEP 3.
20
key. The station will save the data about the amount of old oil removed from the
key. The station will start cleaning the
key.