Roland JV-1010 Manual Del Usuario página 86

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Aplicación MIDI
I Examples of Actual MIDI Messages
<Example 1> 92 3E 5F
9n is the Note On status and `n' is the MIDI channel number. Since 2H = 2, 3EH = 62, and
5FH = 95, this is a Note On message of MIDI CH = 3, note number 62 (note name D4) and
velocity 95.
<Example 2> CE 49
CnH is the Program Change status and `n' is the MIDI channel number. Since EH = 14, and
49H = 73, this is a Program Change message of MIDI CH = 15, Program number 74 (in the
GS sound map, Flute).
<Example 3> EA 00 28
EnH is the Pitch Bend Change status and `n' is the MIDI channel number. The 2nd byte
(00H=0) is the LSB of the Pitch Bend value, and the 3rd byte (28H=40) is the MSB. However
since the Pitch Bend is a signed number with 0 at 40 00H (= 64 x 128 + 0 = 8192), the Pitch
Bend value in this case is 28 00H - 40 00H = 40 x 128 + 0 - (64 x 128 + 0) = 5120 - 8192 = -3072
If we assume that the Pitch Bend Sensitivity is set to two semitones, the pitch will change
only -200 cents for a Pitch Bend value of -8192 (00 00H). Thus, this message is specifying a
Pitch Bend of -200 x (-3072) / (-8192) = -75 cents on MIDI CH = 11.
<Example 4> B3 64 00 65 00 06 0C 26 00 64 7F 65 7F
BnH is the Control Change status, and `n' is the MIDI channel number. In Control Change
messages, the 2nd byte is the controller number, and the 3rd byte is the parameter value.
MIDI allows what is known as "running status," when if messages of the same status follow
each other, it is permitted to omit the second and following status bytes. In the message
above, running status is being used, meaning that the message has the following content.
B3 64 00
MIDI CH = 4, RPN parameter number LSB: 00H
(B3) 65 00
MIDI CH = 4, RPN parameter number MSB: 00H
(B3) 06 0C
MIDI CH = 4, parameter value MSB: 0CH
(B3) 26 00
MIDI CH = 4, parameter value LSB: 00H
(B3) 64 7F
MIDI CH = 4, RPN parameter number LSB: 7FH
(B3) 65 7F
MIDI CH = 4, RPN parameter number MSB: 7FH
Thus, this message transmits a parameter value of 0C 00H to RPN parameter number 00
00H on MIDI CH = 4, and then sets the RPN parameter number to 7F 7FH.
The function assigned to RPN parameter number 00 00H is Pitch Bend Sensitivity, and the
MSB of the parameter value indicates semitone steps. Since the MSB of this parameter value
is 0CH = 12, the maximum width of pitch bend is being set to [+/-] 12 semitones (1 octave)
(GS sound sources ignore the LSB of Pitch Bend Sensitivity, but it is best to transmit the LSB
(parameter value 0) as well, so that the message can be correctly received by any device.
Once the parameter number has been set for RPN or NRPN, all subsequent Data Entry
messages on that channel will be effective. Thus, it is recommended that after you have
made the change you want, you set the parameter number to 7F 7FH (an "unset" or "null"
setting). The final (B3) 64 7F (B3) 65 7F is for this purpose.
It is not a good idea to store many events within the data of a song (e.g., a Standard MIDI
File song) using running status as shown in <Example 4>. When the song is paused, fast-
forwarded or rewound, the sequencer may not be able to transmit the proper status, causing
the sound source to misinterpret the data. It is best to attach the proper status byte to all
events.
It is also important to transmit RPN or NRPN parameter number settings and parameter
values in the correct order. In some sequencers, data events recorded in the same clock (or a
nearby clock) can sometimes be transmitted in an order other than the order in which they
were recorded. It is best to record such events at an appropriate interval (1 tick at TPQN=96,
or 5 ticks at TPQN=480).
* TPQN: Ticks Per Quarter Note (i.e., the time resolution of the sequencer)
86
I Examples of Exclusive Messages and
Calculating the Checksum
Roland exclusive messages (RQ1, DT1) are transmitted with a checksum at the end of the
data (before F7) to check that the data was received correctly. The value of the checksum is
determined by the address and data (or size) of the exclusive message.
❍How to Calculate the Checksum
(hexadecimal values are indicated by a "H")
The checksum consists of a value whose lower 7 bits are 0 when the address, size and
checksum itself are added.
The following formula shows how to calculate the checksum when the exclusive message to
be transmitted has an address of aa bb cc ddH, and data or size of ee ffH.
aa + bb + cc + dd + ee + ff = total
total / 128 = quotient ... remainder
128 - remainder = checksum
<Example 1> Setting the Performance Common REVERB TYPE to DELAY (DT1)
The "Parameter Address Map" indicates that the starting address of the Temporary
Performance is 01 00 00 00H, that the Performance Common offset address is 00 00H, and
that the REVERB TYPE address is 00 28H. Thus, the address is:
01 00 00 00H
00 00H
+)
00 28H
01 00 00 28H
Since DELAY is parameter value 06H,
F0
41
10
6A
12
(1)
(2)
(3)
(4)
(5)
(1) Exclusive status
(2) ID number (Roland)
(4) Model ID (JV-1010)
(5) Command ID (DT1)
Next we calculate the checksum.
01H + 00H + 00H + 28H + 06H = 1 + 0 + 0 + 40 + 6 = 47 (sum)
47 (total) / 128 = 0 (quotient) ... 47 (remainder)
checksum = 128 - 47 (quotient) = 81 = 51H
This means that the message transmitted will be F0 41 10 6A 12 01 00 00 28 06 51 F7.
<Example 2> Retrieving data for USER:03 Performance Part 3 (RQ1)
The "Parameter Address Map" indicates that the starting address of USER:03 is 10 02 00
00H, and that the offset address of Performance Part 3 is 12 00H. Thus, the address is:
10 02 00 00H
+)
12 00H
10 02 12 00H
Since the size of the Performance Part is 00 00 00 19H,
F0
41
10
6A
11
(1)
(2)
(3)
(4)
(5)
(1) Exclusive status
(2) ID number (Roland)
(4) Model ID (JV-1010)
(5) Command ID (RQ1)
Next we calculate the checksum.
10H + 02H + 12H + 00H + 00H + 00H + 00H + 19H =
16 + 2 + 18 + 0 + 0 + 0 + 0 + 25 = 61 (sum)
61 (total) / 128 = 0 (product) ... 61 (remainder)
checksum = 128 - 61 (remainder) = 67 = 43H
Thus, a message of F0 41 10 6A 11 10 02 12 00 00 00 00 19 43 F7 would be transmitted.
01 00 00 28
06
??
F7
address
data
checksum
(6)
(3) Device ID (17)
(6) EOX
10 02 12 00
00 00 00 19
??
address
size
checksum
(3) Device ID (17)
(6) EOX
F7
(6)

Publicidad

Tabla de contenido
loading

Tabla de contenido