E N G L I S H
N. PLATFORM FLIP-UP FOOTPLATE
1. Height Adjustment
a) Remove retaining bolts in the frame tube (A).
b) Slide footplate and extension tubes to desired height.
c) The adjustment on each side of the footrest should be of equal height.
d) Replace and tighten bolts.
2. Angle Adjustment
a) Loosen the nuts under the footplate clamp (B) until the adjustable clamp and footplate
rotate freely on the mounting tube.
b) Adjust the angle of the footplate.
c) Tighten nuts.
O. HEIGHT-ADJUSTABLE ARMRESTS
1. Installation
a) Slide the outer armpost into the receiver mounted to the wheelchair frame.
b) The armrest should lock in place automatically.
2. Removing Armrest
a) Press release lever (A) and remove the armrest.
Q-NOTE– Release lever should move freely. Do not force or over rotate.
3. Height Adjustment
a) Rotate release lever (A) to second stop.
Q-NOTE– Release lever should move freely. Do not force.
b) Slide armrest pad up or down.
c) Return lever to locked position against armpost.
d) Push arm pad until upper armpost locks firmly into place.
e) A snap lock is engaged if the armrest is raised to its highest adjustment. To disconnect
the snap lock, press in on the button head and press the armrest down.
4. Replacing Armrest
a) Slide armrest back into receiver until it stops.
Q-NOTE– Check to make sure release lever is engaged by pulling up on armrest.
5. Adjusting Armrest Receiver Fit
To tighten or loosen the fit of the outer armpost in the receiver:
a) Loosen the four bolts on the side of the receiver.
b) With the armrest in the receiver, squeeze the receiver to achieve the desired fit.
c) Tighten the four bolts.
6. Adjusting Inner Armpost Fit
a) Two set screws (C) are installed in the outer armpost.
b) Turn the set screws in or out until the desired fit is achieved.
P . JOYSTICK & ENHANCED DISPLAY
1. To Connect (Fig. 21)
a. Line up the groove on the joystick cable (A) with the groove on the wing of the wheel-
chair cable (B).
b. Push the connectors together and then turn the wing of the wheelchair cable until the
two wings line up (C).
2. To Disconnect (Fig. 22)
a. Turn the wing (D) so that both the groove on the wing of the wheelchair cable and the
groove on the joystick cable line up.
b. Pull apart the two connectors.
(Fig. 17)
(Optional) (Fig. 18)
(Figs 19, 20, 21, 22)
19
17
A
B
Platform Flip-up
Footplate
18
A
B
C
Height Adjustable
Armrest
19
Qr3 Remote Joystick
20
Enhanced Display
21
B
A
22
C
D
V I I I .
932213 Rev. A