Code
No.
Name
Configuration TRIP
c70
reset (error reset)
Auto-TRIP reset delay
c71
Operating time
c78
counter
Mains connection
c79
time counter
PI setpoint
c81
S-ramp integration
c82
time
Minimum feedback
c86
Maximum feedback
c87
PI setpoint accel/
d25
decel
PI mode
d38
Feedback minimum
d46
alarm
Feedback maximum
d47
alarm
Lenze 13435747 EDBSX03 v17 EN, DE, FR, IT, ES
Possible Settings
Selection
Lenze
0
0
TRIP reset after LOW-HIGH
change at terminal 28, mains
switching, or after LOW-HIGH
change at digital input "TRIP reset"
1
Auto-TRIP reset
WARNING!
Automatic starting/restarting may cause damage to equipment and/or injury to
personnel! Automatic starting/restarting should only be used on equipment that is
inaccessible to personnel.
0.0
0.0
{s}
Display
Total time in status "Start"
Display
Total time of mains = on
0.0
c86
0.0
0.0
{s}
0.0
0.0
100
0.0
5.0
0.0
{s}
0
0
PI disabled
1
PI enabled: normal-acting
2
PI enabled: reverse-acting
0.0
0.0
0.0
0.0
Commissioning
• Auto-TRIP reset after the time set in
c71
• More than 8 errors in 10 minutes will
rSt
trigger
60.0
See c70
0...999 h: format xxx
1000...9999 h: format x.xx (x1000)
10000...99999 h: format xx.x (x1000)
c87
50.0
• c82 = 0.0: Linear accel/decel ramp
• c82 > 0.0: Adjusts S-ramp curve for
smoother ramp
999
• Select feedback signal at C34
• If feedback is reverse-acting, set
999
c86>c87
999
Sets rate of change for PI setpoint
When feedback (terminal 8) exceeds
setpoint, speed decreases
When feedback (terminal 8) exceeds
setpoint, speed increases
999
See C08, selections 9 and 10
999
IMPORTANT
fault
17