Erreka PUMA-I Guía Rápida De Instalación Y Programación página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
(ST2)
SG. A
(FT2)
Motor with
no capacitor
DL1
Automatic closing LED
DL2
Radio programming LED
DL3
Travel programming LED
DL6
FT2 photocell LED
Encoder (DIP7): for the correct operation of the encoder, ensure DIP7 is in ON. The operation needs to be
reprogrammed if the encoder is disabled.
Check that DL21 flashes during gate movement.
Turning direction: check operation using ST1 and ST2 mini-pushbuttons with DIP1=ON. If turning direction is not as
indicated for position DIP6, interchange the wires connected to the G1 and G2 terminals.
10
General connections
A capacitor should not be used for the motor with the PUMA-I
operator fitted with Inverter technology control board.
(ST1)
(FT1)
PEDESTRIAN
(12Vdc)
G2
G1
C
DL7
DL8
DL9
DL10
Check and configure turning direction and limit switches
DIP6=OFF
SW1 Functions during programming (DIP1=ON)
DIP1=ON: programming enabled (DL3 lights up); ST1: open, ST2: close
DIP1=ON and DIP2=ON: total open/close programming
DIP1=ON and DIP3=ON: pedestrian open/close programming
SW1
DIP1=ON and DIP4=ON: total opening radio code programming
DIP1=ON and DIP6=ON: pedestrian opening radio code programming
E268L
FC1
(DIP6=OFF: FCA)
(DIP6=ON: FCC)
TOTAL
ST1
DL11
DL7
DL1 DL2 DL3
DL9
ST2
DL10
DL6
F5-3A
SW2
FC1 limit switch LED
FC2 limit switch LED
FT1 photocell LED
ST2 pushbutton LED
R.E.
(DIP6=OFF: FCC
(DIP6=ON: FCA)
DL8
DL21
SW1
F1-0,315A
DL26
F6-0,5A
DL11
ST1 pushbutton LED
DL21
Encoder LED
DL26
DC Bus LED
DIP6=ON
FC2
P268Y

Publicidad

Tabla de contenido
loading

Tabla de contenido