otherwise make it be replaced by qualified personnel with another section and type
5G4 H07RN-F (for version 400 V), 4G4 H07RN-F (for version 230/3 V) before
connecting the machine to the mains.
• Arrange the connection of the yellow-green wire to a good earth connection.
• Put the machine metallic parts to earth by means
of the apposite equipotent fastening screw
located on the back under the frame and marked
by the symbol showed on the left.
• Make sure that the water supply system is
provided with sufficient pressure for a correct
operation of the condensing plant. A residual
pressure ranging between 1 bar and
considered suitable.
• Connect the condensing water inlet hose to the
inlet showed in the picture by means of a rubber
hose Ø1/2". Interpose a cut-off cock
operator's reach.
• Connect the condensing water outlet hose to the
outlet showed in the picture by means of a hose
connector Ø1/2" and bring it to the discharge.
• Both for inlet and outlet connections it is
advisable to make use of linenized hoses suitable
to withstand pressures up to 10 bar and apposite
hose clamps DIN 3017.
• The water outlet hose shall have a min.
inclination of 3 cm for each meter of length.
• In case of water condensing it is necessary to
check that the water valve correctly works.
• After both inlet and outlet hoses have been
connected, open the cut-off cock and make sure
that the discharge does not leak liquid when the
machine is not working. If this is the case, apply
to a qualified customer service.
• After the master switch has been turned on, press
pushbutton
PRODUCTION to
compressor
motor;
condensing water shall regularly come out of the
draining pipe at a temperature of about 35°C.
Press STOP pushbutton to stop the machine. In
case of troubles, apply to the service centre.
• Check for the correct direction of rotation of the
agitator motor: apply voltage to the machine,
press CLEANING and check through the hopper
grid that the rotation direction of the agitator is
counterclockwise. If not, exchange the wires in