- Press
to display the imbalance
values (recalculated for the new dimen-
sions) or
perform a wheel spin.
Balancing weight application
- Select the plane where the first balancing
weight is to be applied.
- Turn the wheel until the central element of
the corresponding position indicator lights
up.
If the weight to be applied is a conventional
clip type(inner side in Alu 2P), apply it on the
corresponding 12 o'clock position.
If the weight to be applied is self-adhesive,
proceed as follows:
VERSION WITH AUTOMATIC SENSOR
- Turn the wheel until the central element of
the corresponding position indicator lights
up.
- Apply the adhesive weight manually at 12
o'clock in the position in which the relative
plane was measured, using the centre of
gravity of the weight itself as reference.
VERSION WITH MANUAL SENSOR
with the wheel in the centred position the
machine screen displays the imbalance
value:
- Turn the wheel until the central element of
the corresponding position indicator lights
up.
- Apply the adhesive weight manually at 12
o'clock in the position in which the relative
plane was measured, using the centre of
gravity of the weight itself as reference.
User manual ProLine 640
The rim surface must be perfectly clean to
make the weight stick efficiently to the rim.
If necessary, clean the surface using suitable
cleansing products.
"Shift planes" programme (available
only with Alu p programmes)
This function is automatically enabled when
an ALU P programme is selected.
It modifies the selected positions for the
application of adhesive weights, so as to
ensure perfect balancing of the wheel
using commercially available adhesive
weights (i.e. multiples of five grams). The
accuracy of the machine is thereby improved,
avoiding rounding off or cutting the weights
to be applied to come closer to the actual
unbalance values.
The modified positions, where the adhesive
weights are to be applied, are identified by
the user according to the information given
by the wheel balancer (see the BALANCING
WEIGHT APPLICATION section).
"HIDDEN WEIGHTS" PROGRAMME
(available only with the ALU P
programme)
This programme divides the outer weight
Pe into two weights P1 and P2 located in any
position chosen by the operator.
The only condition is that the two weights and
the original outer weight Pe must be within
an angle of 120°, as shown in Fig. 16.
UK