5.12.2 Checking a title sequence
1) If a title is replayed, first set the unit to pause
with the button II .
2) If the indication "PG" flashes now, press the
button PROG once . If the indication "PG"
lights constantly, press the button PROG
twice .
3) Select the storage locations (P− 01 ... P− 99)
successively with the button I or I . The
title stored in each case is indicated in the
text line (O) .
4) To replay the title sequence, press the but-
ton II .
5.12.3 Completing or
deleting a title sequence
1) If a title is replayed, first set the unit to pause
with the button II .
2) If the indication "PG" flashes, keep the but-
ton PROG pressed until "PG" stops flashing .
3) Shortly press the button PROG so that "PG"
flashes quickly and the time indication (P) is
switched over to the indication of the next
free storage location "P−..." .
4) To delete the title sequence, press the button
PROG until the display indicates the play-
ing time (P) again . To complete the title se-
quence, select another title with the button
I or I and confirm with the button PROG .
To replay the completed title sequence, press
the button II .
6 Fader Start
The function Start / Pause of the button II (20)
can be remote-controlled via a mixer with fader
start function . The connection to the mixer is
described in chapter 4, step 3 . Adjust the sliding
switch (34) on the rear side of the player mech-
anism to the type of fader start of the mixer:
LOCK = control via an on / off switch
This switch position must be selected for
most mixers of the IMG STAGELINE range .
By advancing the fader, a switch starting
the replay will be closed in the mixer . When
the fader is closed, the switch will open
and thus set the player unit to pause .
START/
TACT
CUE
PAUSE
LOCK
PLAY
Fig . 8 Fader start via on / off switch
TACT = control via a momentary pushbutton
When the momentary pushbutton is actu-
ated for the first time by advancing the fader,
the replay will start . When the momentary
pushbutton is actuated for the second time
by closing the fader, the player unit will be
set to pause .
START/
TACT
CUE
PAUSE
LOCK
PLAY
Fig . 9 Fader start via momentary pushbutton
CUE PLAY = control via a pulse
When the fader is advanced, the replay will
be started from the title beginning (Auto
Cue point
☞
Cue point set with the button CUE (18)
[
chapter 5 .8 .2] by a short control pulse
☞
of the mixer . When the fader is closed, the
player unit will return to this starting point
by another control pulse and will be set to
pause there .
START/
TACT
CUE
PAUSE
PLAY
LOCK
Fig . 10 Fader start via control pulse
7 Updating the Firmware
If a new firmware is available on the Internet, the
firmware of your unit may be updated:
1) On the homepage of IMG STAGELINE (www .
imgstageline .com), click the tab SERVICE .
Scroll to the section DOWNLOAD SERVICE,
enter the unit name "CD-292USB" and click
the button SEARCH .
When a new firmware is shown, click the
symbol
to download the firmware .
Copy the software you have downloaded to
a USB flash drive .
2) Switch off the CD-292USB with the power
switch (28) .
3) Insert the USB flash drive with the new firm-
ware into the left USB port USB 1 (26) .
4) At the left player unit, keep the button PROG
(13) pressed and switch on the player again .
Do not release the button PROG until the left
display shows "UP dA t E" .
Mixer
5) After reading in, when "Ready" appears in
Start
Pause
the text line (O), press the button II (20)
to start the firmware update . By means of
the bargraph indication (H) and the text line,
the update can be observed . When "Finish"
is shown, the firmware has been updated .
6) Switch off the player and switch it on again .
All rights reserved by MONACOR
may be reproduced in any form or by any means for any commercial use.
Mixer
1. × Start
2. × Pause
chapter 5 .4 .1) or from the
1. × Cue Play
2. × Pause
Mixer
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual
8 Maintenance of the Unit
Protect the unit from dust, vibrations, humidity
and heat (admissible ambient temperature range
0 – 40 °C) . For cleaning only use a dry, soft cloth,
never use water or chemicals .
Note concerning sound interruptions and
reading errors
Cigarette smoke and dust will easily penetrate
through all openings of the unit and also settle
on the optics of the laser sampling system . This
deposit may cause reading errors and sound
interruptions, the unit must then be cleaned by
skilled personnel . This cleaning will be charged,
even during the warranty period!
9 Specifications
Frequency range: . . . . .20 – 20 000 Hz
THD: . . . . . . . . . . . . . . .< 0 .1 %
Channel separation: . . .> 80 dB
Dynamic range: . . . . . . .> 80 dB
S / N ratio: . . . . . . . . . . .> 80 dB
Output: . . . . . . . . . . . . .2 V (line level),
RCA jacks
Readable file systems: . .NTFS, FAT, HFS+
Anti-shock memory: . . .15 s
Power supply: . . . . . . . .230 V / 50 Hz
Power consumption: . . .40 VA max .
Ambient temperature: .0 – 40 °C
Dimensions (W × H × D)
Control unit: . . . . . . . .482 × 90 × 85 mm,
2 rack spaces
Player mechanism: . . .482 × 90 × 260 mm,
2 rack spaces
Weight: . . . . . . . . . . . .6 .5 kg
Subject to technical modification .
15