Initial Setup; Hanging The Tubes - L.B.White Oval 80 HP Instrucciones Y Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

12
Oval 80 Radiant Tube Heaters
17. Any defects found in performing any of the service
procedures must be eliminated and defective parts
replaced immediately. Retest the heater before
placing it back into service.
18. Do not exceed input rating stamped on the
dataplate of the heater. Do not exceed the burner
manifold pressure stated on the dataplate. Do not
use an orifice size different than specified for the
specific input rating of this heater, fuel type configu-
ration and altitude.

Initial Setup

1. Plan the installation. Determine location for the heater
to optimize its heat pattern, keeping in mind cooler
regions in the house (end walls, and curtains) and
clearances to combustibles.
2. Hang the burner box. See Fig. 5. Maintain clearances
to combustibles as shown in Fig. 1.
3. From the burner box chain, measure the distances
shown in Fig. 6 or 7. Aligning to the center
of the burner box discharge, hang chains at
these points, using open eye hooks.
FIG. 5
JOIST
OPEN EYE HOOKS
IN LINE WITH
EYE BOLTS ON
BURNER BOX
OPEN EYE BOLT
1 ft.
.30m
BURNER
DISCHARGE
Owner's Manual • Oval 80
FIG. 6
FIG. 6
A

Hanging the Tubes

Refer to Fig. 7 (on next page) and the following instructions:
1. Slide a tube clamp over the non-swaged end of the 10 ft.
bright aluminized tube.
2. Install the tube over the swaged discharge tube on the
burner box:
a. Tube weld seam must be down.
b. Non-swaged end of tube must be
completely pushed over swaged end of
10
adjoining tube.
c. Clamp must be centered over tube
connection.
d. Clamp bolts must be up.
e. Clamp bolts must be tight.
-- Tighten both bolts firmly.
-- Tighten both bolts to 35 ft.-lbs.
-- Finish tightening bolts to 44-59 ft. lbs.
TIGHTEN HOOKS
SECURELY
BURNER BOX
BURNER BOX
B
C
D
HANGING CHAIN DISTANCES
TRUSS
HEATER
A - B B - C C - D D - E
CENTERS
LENGTH
(FT)
20 FOOT
4
4 FOOT
50 FOOT
4
20 FOOT
5
5 FOOT
50 FOOT
5
5*
20 FOOT
50 FOOT
5
10 FOOT
* A SUPPORT MUST BE CREATED BETWEEN THE TRUSS
BURNER
DISCHARGE
HANGING CHAINS
HANGING CHA
E
F
(FT)
(FT)
(FT)
4
8
4
4
8
12
5
5
5
5
10
10
5*
5
5
5
10
*
10

Publicidad

Capítulos

Tabla de contenido
loading