Figure 2-1: Opening the Panel Mount Enclosure

Harsh Enclosure

The front panel of the harsh enclosure IND780 terminal is locked in place by four
spring clips attached to the enclosure body. To gain access to the terminal's PCB
for internal wiring and setting switches, separate the front panel from the enclosure
as follows:
1. Place the terminal on a stable, flat surface, with its front panel facing up.
Figure 2-2: Opening the Harsh Enclosure
2. Insert the tip of a flat blade screwdriver into one of the two slots located on the
edge of the front panel assembly (see Figure 2-2). Squeeze the top of the front
panel firmly down against the enclosure, in order to relieve the pressure on the
retaining clip, and push the screwdriver in toward the enclosure until a "pop"
sound is heard.