Assisted Procedure; Recovery And Recycling - Launch VALUE-200 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 123
N.B. – The automatic procedure may be run even if the A/C system is empty. In this case the
machine will begin with the vacuum phase. When working with A/C systems with a single
high-pressure coupling, set the charging quantity at about 100g in excess of the required
quantity, since in this case it will be impossible to recover the residual refrigerant from the
hoses.
NOTE: If STOP is pressed during recovery, the following screen will be displayed:
Press START to restart the procedure. If STOP or RESET is pressed the following message
will be displayed:
Press START to restart the procedure; press STOP or RESET to return to the MAIN MENU.
If RESET is pressed during recovery, the following message will be displayed:
Press START to restart the procedure; press STOP or RESET to return to the MAIN MENU..

ASSISTED PROCEDURE

In the assisted procedure mode, all the operations can be performed singly to the exception of
the recovery/recycling phase, which is automatically followed by used oil discharge. The values
for the quantity of gas recovered, quantity of oil recovered, vacuum time, quantity of oil
reintegrated, and quantity of gas charged into the system are automatically printed at the end
of each single operation.

RECOVERY AND RECYCLING

Connect the hoses to the A/C system with the quick-connect couplings, bearing in mind that
BLUE must be connected to the low-pressure side and RED to high pressure. If the A/C
system is equipped with a single quick-connect coupling for high or low pressure, connect only
the relative hose. Check that the high- and low-pressure taps are closed. Start the vehicle
engine and the air conditioner and allow both to run for 5 to 10 minutes with the passenger
compartment fan at full speed. Switch off the vehicle engine. Select the assisted procedure by
pressing ENTER when "Assisted Procedure" flashes on the LCD. Select recovery and
recycling by pressing ENTER when "Recovery/Recycling" flashes on the LCD.
Open the high and low pressure taps on the machine and press the START key to begin the
refrigerant
recovery/recycling
"Recovery/Recycling". During this phase, the machine displays the quantity of refrigerant
recovered, in grams (g).
INSTRUCTIONS MANUAL
Procedure paused.
START to continue
STOP to abort procedure
ATTENTION
STOPPING RECOVERY BEFORE
OIL DISCHARGE
MAY DAMAGE
THE COMPRESSOR
START TO CONTINUE
ATTENTION
STOPPING RECOVERY BEFORE
OIL DISCHARGE
MAY DAMAGE
THE COMPRESSOR
START TO CONTINUE START
PER CONTINUARE
phase,
which
will
-13-
be
signaled
on
the
LCD
as

Publicidad

Tabla de contenido
loading

Productos relacionados para Launch VALUE-200

Tabla de contenido