THE MACHINE

BASIC COMPONENTS

Refer to Figures 5, 6, 7 and 8.
a) Control consoles
h) Wheels
m) Used oil tank
bi) Oil scale
e) Drying filters
r) Heating resistance
i) Main switch
k) Fuse
f) Vacuum pump
v) Air purge valve

CONTROLS AND CONTROL SYSTEM

Refer to Figure 9.
A1) High pressure gauge
A3) Keyboard
A5) LCD: 4 lines, 20 characters

FUNCTION SELECTOR KEYBOARD

STOP: Press to interrupt the operation being performed in the case of the principal functions:
recovery - oil discharge - vacuum/oil reintegration - charging). Press START to resume
operation from the point of interruption. Pressing STOP during an alarm state, error state, or
end-of-operation silences the audible alarm.
RESET: Press to interrupt the operation being performed. The procedure may be restarted
from the beginning.
ENTER: Press to confirm the procedure or operation flashing on the LCD.
↓: Press to move downward from one procedure or operation to another within a menu.
↑: Press to move upward from one procedure or operation to another within a menu.
START: Press to launch the procedure or operation shown on the display.

ALARMS

HIGH PRESSURE ALARM: Beeper and led advise when the pressure of the fluid in the circuit
reaches 17.5 bar. The recovery operation is automatically interrupted.
FULL BOTTLE ALARM: Beeper and led advise when the bottle is filled to more than 80% of
maximum capacity; that is, 10 kg. The RECOVERY operation is automatically interrupted (to
cancel this alarm, charge one or more A/C systems before recovering any more refrigerant).
EMPTY BOTTLE ALARM: Beeper and led advise when the quantity of refrigerant fluid
contained in the bottle is low.
SERVICE ALARM: Beeper and led advise whenever the total recovered refrigerant amounts to
150 kg. To deactivate the alarm, replace the filters and the vacuum pump oil. A code for
canceling the alarm is supplied with the spare filters.
AIR PURGE ALARM: Beeper and led advise when there is air inside the bottle when the
machine is switched on. To deactivate the alarm, purge the air from the bottle.
INSUFFICIENT GAS ALARM: Beeper and LED advise when the charging quantity set
exceeds the difference between availability and bottle minimum.
INSTRUCTIONS MANUAL
z) Tracer bottle (if installed)
b) Taps
l) High/Low Pressure threaded connectors
n) New oil tank
d) Bottle
o) Electronic scale
ps) Serial port
j) Socket for electrical supply plug
c) Moisture indicator
u) USB port
w) collapsible tracer cartridge (if installed)
A2) Low pressure gauge
A4) Bottle pressure gauge
A6) Printer