the circuit (inner circle yellow). Before performing any operation, check that the replacement
filters are the same types as those installed on the machine. Then proceed as described below
(refer to Fig. 11):
1) Disconnect the machine from the electrical supply
2) Wear protective gloves and glasses
3) Remove the rear plastic cover from the machine.
4) Close the taps on the bottle.
5) Close the tap (1) on the filter (4).
6) Connect the low pressure quick-connect coupling to the male connector (2) of the filter
(4).
7) Connect the machine to the electrical supply.
8) Carry out a recovery operation (note: the low pressure tap should be open).
9) When zero bar is reached, immediately close the tap (3) on the filter (5) and press Stop
or Reset.
10) Disconnect the machine from the electrical supply.
11) Disconnect the low pressure quick-connect coupling from the connector (2) on the filter
(4).
12) Remove the used filters and install new ones, respecting the direction of the arrows.
IMPORTANT: Filter replacement must be performed as quickly as possible in order
to avoid possible contamination by moisture in the ambient air.
13) Open the tap (1) under the filter (4) and the tap (3) on the filter (5).
14) Open the taps on the bottle.
NOTE: If possible, check the seal on the couplings of the new filters, using an electronic
leak tester.
15) Replace the rear plastic cover on the machine.
16) Reconnect the machine to the electrical supply and switch on.
17) Select NEXT MENU, and enter SERVICE ALARM.
18) Key in the filter code to cancel the alarm. If the filter code is not available, call the
Service Center.
19) Recover about 500g of gas to charge the machine circuit.
20) Switch the machine off.
21) Disconnect the machine from the electrical supply.

FILLING THE NEW OIL CONTAINER

It is good practice to fill the oil container whenever the oil level falls below 100 cc in order to
guarantee that there will be sufficient oil for topping up during successive operations. Types of
oil: use only synthetic (polyester) oils or the oils recommended by the manufacturer. Always
refer to the information provided by the A/C system manufacturer. Procedure: remove the
container from its lodging. Hold the cap and unscrew the container. Fill the container with the
correct quantity of oil for compressors, of suitable type and grade. Screw the container back
into the cap while holding the latter in place. Replace the container, taking care not to exert
pressure on the scale in order not to damage it.

FILLING THE TRACER CONTAINER (if installed)

It is good practice to refill the tracer container whenever the level drops below 50 cc, in order to
have a sufficient reserve of tracer for carrying out subsequent fillings. Procedure: Lift the tracer
container out of its lodging. Unscrew the container while holding the cap in place and fill the
container with the required quantity of tracer for compressors. Screw the container back onto
the cap and return to its lodging, taking great care not to exert pressure on the scale in order
not to damage it.
N.B.: Using tracers not recommended by the manufacturer will invalidate the warranty.

REPLACING THE COLLAPSIBLE TRACER CARTRIDGE (if installed)

We recommend replacing the tracer cartridge when tracer level is low (a few ccs) in order to
always have sufficient reserves for use.