With BOTTLE SCALE flashing, press ENTER. The following screen will be displayed:
Press the ENTER key.
With the bottle lifted off the scale plate, press START. The following screen will be displayed:
Place the reference weight (16 to 18 kg) at the center of the scale plate. Use keys 0 through 9
to type in the value of the weight. Press START. Select "PREVIOUS MENU" to exit the
CALIBRATION MENU. Press START to save the data. Switch off the machine and disconnect
it from mains supply. Replace the bottle on the scale plate and the heating coil on the bottle
(Attention: the resistance must adhere tightly to the bottle). Replace the plastic cover. Open
the blue and red taps on the bottle. Replace the rear plastic cover.

BOTTLE DATA

N.B. This menu is reserved for use by the technician performing final testing. It contains the
maximum safety threshold value; therefore, the bottle data may not be changed for any reason.
For assistance, call the Service Center.
Access the CAILIBRATION MENU as explained above.
The following screen will be displayed:
With the BOTTLE SCALE message flashing, press the ENTER key. The following screen will
be displayed:
Select BOTTLE DATA. The following screen will be displayed:
INSTRUCTIONS MANUAL
<BOTTLE SCALE >
OIL SCALE
BOTTLE TEMPERATURE
CALIBRATION
BOTTLE DATA
PREVIOUS MENU
ZERO LEVEL
Raise the bottle
levels
xxxxx
press START
REFERENCE VALUE
xxxxx g
levels
xxxxx
press START
<BOTTLE SCALE >
OIL SCALE
BOTTLE TEMPERATURE
CALIBRATION
<BOTTLE DATA>
PREVIOUS MENU
-21-