Technical Specifications - Viking ME 545 Manual De Instrucciones

Ocultar thumbs Ver también para ME 545:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 111
The product has been developed in
conformance with the following standards:
EN 60335-1, EN 60335-2-77
Applicable conformity assessment
procedure:
Appendix VIII (2000/14/EC)
Name and address of relevant, named
location:
TÜV Rheinland LGA Products GmbH
Tillystraße 2
D-90431 Nürnberg
Compilation and storage of technical
documentation:
Sven Zimmermann
VIKING GmbH
The year of manufacture and serial
number appear on the identification plate
of the machine.
Measured sound power level:
93,6 dB(A)
Guaranteed sound power level:
94 dB(A)
Langkampfen,
2017-01-02 (YYYY-MM-DD)
VIKING GmbH
Head of Design
0478 121 9909 H - EN

18. Technical specifications

ME 545.1, ME 545.0 C, ME 545.0 V:
Serial number
6340
Motor, design
Electric motor
Motor manufacturer
ATB
Motor type
BSRBF 0,75/2-
C74
Voltage
230 V~
Power input
1600 W
Frequency
50 Hz
Fuse
10 A
Protection class
II
Type of protection
IPX 4
Cutting utilities
Cutter bar
Cutting width
43 cm
Speed of cutting
utilities
2800 rpm
Cutter bar drive
Permanent
Tightening torque for
blade fastening
screw
15 - 20 Nm
Wheel diameter
(front)
180 mm
Wheel diameter
(rear)
200 mm
ME 545.0 V: Self-
propulsion, rear
wheels
Vario gearbox
Grass catcher box
capacity
60 l
Cutting height
25 - 80 mm
Length
147 cm
Width
48 cm
Height
102 cm
Weight:
ME 545.1
26 kg
ME 545.0 C
29 kg
ME 545.0 C (GB)
30 kg
ME 545.0 V
31 kg
Sound emissions:
In accordance with Directive 2000/14/EC:
Guaranteed sound
power level L
94 dB(A)
WAd
In accordance with Directive 2006/42/EC:
Sound pressure level
at workplace L
82 dB(A)
pA
Uncertainty K
2 dB(A)
pA
Hand-arm vibrations:
Specified vibration characteristic in
accordance with EN 12096:
Measured value a
2,80 m/sec
hw
Uncertainty K
1,40 m/sec
hw
Measurement in accordance with
EN 20643
19. Troubleshooting
If necessary, contact a specialist
dealer; VIKING recommends VIKING
specialist dealers.
Fault:
Motor not starting
Possible cause:
– No mains voltage
– Electric cable/plug and plug connector
or switch defective
– ON button not pressed
– Motor is overloaded because the grass
is too tall or too wet
– Motor overload protection activated
– Mower housing is blocked
2
2
45