Rautheon UW50PV Manual De Operation página 19

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Display Interpretations (Continued)
W3
Wash 3 (no agitation)
W4
Wash 4 (medium reversing action)
W5
Wash 5 (temp.-controlled cool-down)
W6
Wash 6 (extra low agitation)
W7
Wash 7 (no agitation, drain 1 open,
no refill)
WF
Warm flush
WH
Warm fill to high level
WM
Warm fill to medium level
WL
Warm fill to low level
WO
Warm fill to overflow level
WR
Warm rinse
Left dot – poor balance condition
Second dot from left – door lock switch
Third dot from left – program mode
Fourth dot from left – high level
reached
Fifth dot from left – medium level
reached
Right dot – low level reached
EXISTS
Cycle already in memory
EDIT?
Do you want to edit the cycle?
TEMP
Over-temperature-limit condition
OVERHT
Open or shorted temperature input
circuit or temperature out of
computer's allowable limits
WATER
Water in washer-extractor at end of
cycle
°FAR
Temperature in degrees Fahrenheit
°CEN
Temperature in degrees Centigrade
MANUAL
Manual Mode enabled
F232050
Display Interpretations (Continued)
NO MAN
Manual Mode disabled
1DRAIN
One drain capability selected
2DRAIN
Second independent drain enabled (via
Auxiliary 2 output – precludes control
of recirculation pump via Auxiliary 2,
if selected). This should not be
confused with the "dual drain" option.
ADV
Advance (skip steps) feature enabled
NO ADV
Advance feature disabled
WET CL
Wet clean function for Auxiliary 1
output (1/2 wash speed) and Auxiliary
2 output (recirculation pump) enabled
(See "2DRAIN.")
NO WCL
Wet clean function for Auxiliary 1 and
2 disabled (Auxiliary 1 and 2 are
timed outputs.)
S BAL
"Short" balance routine – active only if
inverter drive load balance sensing is
utilized.
L BAL
"Long" balance routine – active only if
AC inverter drive load balance sensing
is utilized.
Operation
17