Note: If "NO WCL" is selected in the
prompting process, Auxiliary 1 operates
as a timed output (remains on for the time
programmed).
6. Recirculation Pump. The computer must
be prompted for "1DRAIN" and "WET
CL." Also, a second drain should not be
connected to the Auxiliary 2 output if the
recirculation pump is used. However, a
second independent drain will operate
properly when connected to the Auxiliary
2 output if the WE-6 is prompted for
"2DRAIN." Thus, one machine cannot
have both a recirculation pump and a
second independent drain.
Note: This is not the same as the "dual drain"
option. Dual drain models operate the two
drains simultaneously. A second independent
drain, on the other hand, can be programmed
to operate independently of the main drain
(drain 1) if "2DRAIN" is prompted. Such a
drain step would be programmed by selecting
a "Danncc" or "Dbnncc" step. This capability
would only be used in special applications and
is not for use with standard wet cleaning
applications. Therefore, the drain should be
prompted for "1DRAIN".
The Auxiliary 2 output remains on until a
drain step is activated or until the stop
routine is initiated. Also, the computer will
turn off the Auxiliary 2 output
(recirculation pump) upon entering
a Wash 7 step.
F232050
Programming
Note: The WE-6 precludes operation of the
recirculation pump if the temperature exceeds
160 degrees Fahrenheit (71 degrees
Centigrade) for the remainder of the step in
effect at the time.
Note: If "NO WCL" and "1DRAIN" are
selected in the prompting process, Auxiliary 2
operates as a timed output (remains on for the
time programmed).