Programming Tutorial

The following procedure guides the
programmer through a complete cycle and
allows hands-on experience for programming
cycles. The complete cycle is listed in the
Tutorial Cycle table at the end of this section.
1. Locate the key-operated programming
switch on the left side of the control
module, viewed from the front. Insert the
key and turn the switch to PROGRAM
position. The display will read "CYC00."
2. Press the Add Cycle key. The display will
read "ACYC00."
3. A two-digit number from 01 to 39 must be
entered. Cycle number 39 is recommended
because standard program versions use
this short cycle for performing a chemical
supply setup.
4. Press key 3, then key 9, then the Enter
key. The display will read "CYC39."
a. If the display alternately flashes
"EXISTS" and "EDIT?," press the
Clear/Stop key. The display will
read "CYC39."
b. Erase the existing cycle: Press the
Erase Cycle key. The display will
show "ECYC39." Press key 3, then
key 9, then the Enter key. The display
will read "WAIT" briefly and then
"CYC39."
c. Press the Add Cycle key. The display
will read "ACYC39." Press key 3, then
key 9, then the Enter key. The display
will show "0139."
5. Enter the desired function for step 1.
A natural choice might be hot fill to
low level.
F232050
Programming
a. Press the Hot key and then the Low
key. The display will read "HL0139."
b. Press the Enter key. The display will
read "M---S."
c. Now enter the desired fill time. The
recommended number of minutes is
four. Press key 4. The display will
read "4M-00S."
6. Now press the Enter key. The display will
read "0239," indicating that the computer
is ready for step 2 of cycle 39.
7. A natural choice for step 2 is the addition
of a supply.
a. To add supply No. 1, press the Supply
key and then key 1. The display will
read "S10239."
b. Press the Enter key and the display will
read "M---S."
c. Now enter the desired time in minutes
and seconds for the supply valve to
be turned on. Thirty seconds is the
recommended time.
Press key 0 for minutes, and the display
will read "0M-00S."
Now press key 3 and then key 0. The
display will read "0M-30S," indicating
a supply time of thirty seconds.
8. Now press the Enter key. The display will
change to read "0339," indicating that the
computer is ready for step 3.
31