Operation
When the computer receives all these inputs
within the three-second time limit, it will
enter the manual mode for the time assigned.
The computer display will flash between
"MAN230" (reflecting the time chosen in
step 2 of the above procedure) and the current
cycle step display for four seconds.
Note: If "NO MAN" is prompted and the
normal key sequence for manual mode is
entered, the computer will display only the
remaining cycle time.
After four seconds, the display will flash
between "MANUAL" and the current cycle
step display for the remainder of the
assigned time.
Manual mode operation will automatically
end when the assigned time elapses. Normal
program timing will then resume from the
same point in the cycle where the manual
mode was entered. To exit the manual mode
and return to normal program timing before
the assigned time elapses, press the Start key.
All water fill and spray rinse valves, supplies,
heat (if the washer-extractor has reached low
water level), and auxiliary outputs can be
manually controlled. The heat output requires
that only the Heat key be pressed. All other
outputs require that two keys be pressed. For
example, to turn on the cold fill valve, press
the keys Cold and Fill. When an output is on,
pressing the same key or keys which caused it
to energize will turn it off. Thus, to turn off the
cold fill valve, press the keys Cold and Fill
once again.
27
F232050