During the cool-down, the drain will remain
closed and water will exit through the
overflow connection. The cylinder will rotate
in a normal reversing mode as during a
Wash 1 step.
Assuming that the computer is in the program
mode and that a heat step has been created and
entered, use the following procedure to
program the thermal cool-down. (Do not
program a drain step before the Wash 5 step.)
1. Press the Wash key and then key 5. The
display will read "W5nncc."
2. Press the Enter key. The display will
read either "080Fcc" or "025Ccc,"
depending on whether Centigrade or
Fahrenheit is prompted.
3. Enter the desired temperature for the load to
cool down to. Three digits must be used for
the temperature. If the desired target
temperature is less than 100 degrees, the
first digit must be "0." The valid
temperature range is 80 – 200 degrees
Fahrenheit and 25 – 93 degrees Centigrade.
The computer will not accept temperatures
out of this range. (The cool-down rate will
be affected by the temperature of the cold
water available.) If 100 degrees Fahrenheit
is selected, the display will read "100Fcc."
4. When the desired cool-down temperature
is displayed, press the Enter key. The
display will show "H---M." Now enter the
maximum time in hours and minutes
for the computer to reach the target
cool-down temperature.
F232050
Programming
Experimentation may be necessary to
determine the exact time required with
each installation to enable the computer
to reach the target cool-down temperature.
Use the edit feature to revise the Wash 5
step during the experimentation process.
When the computer performs the Wash 5
step, the temperature in the sump must be
greater than the target cool-down
temperature. Otherwise, the computer
will advance past the Wash 5 step.
5. When the desired time is displayed, press
the Enter key and go to the next step in
the cycle.

Programming No Reversing

All agitation is programmed by first pressing
the Wash key and then pressing either key 1, 2,
3, 4, 5, 6, or 7 for the type of agitation desired
during the wash step.
If no reversing is desired (rotation continuous
in one direction), use the following procedure:
a. Press the Wash key.
b. Then press either key 1 or key 2.
c. Then press the No Reverse key.
d. Then press the Enter key.
The display will show either "W1nncc" or
"W2nncc," depending on the kind of agitation
selected. The display will not indicate that the
no-reverse option was selected, but the
machine will obey the instructions.