BR70
Weight-tare indicator
9. TECHNICAL PARAMETERS
You can press
,
,
FUNCTION
SUB-FUNCTION
P1 REF
AZN 0
0-AUTO
0-RANGE
SPEED
P2 CAL
DECI
INC
CAP
CAL
P3 PRO
GRA
COUNT
RESET
P4 CHK
MODE 1
MODE 2
MODE 3
MODE 4
User's guide
key to enter setting mode at PROG mode.
DESCRIPTION
This option is used to select the auto zero maintain. Options: O.5d, 1d, 2d, 4d
This option is used to select the auto zero range when turn the indicator.
Options: 0%, 2%, 5%, 10%, 20%
This option is used to select the manual zero
range when press the
Set the ADC speed 7.5/15/30/60 times/second
This option is used to select the decimal. Options : 0, 0.0, 0.00, 0.000
This option is used to select the division. Options : 1, 2, 5, 10, 20, 50
This display will show xxxxxx for setting the capacity.
Calibrate, see detail in SECTION 10.
Parameter of factor gravit adjustment.
This display will show xxxxxx for indicating the internal counts.
This display will show "SURE" for recovering the factory default setting.
This is mode of the natural scale.
This is parameter of the animal scale.
This is the scale subtract (to print "-" weigh)
Printing format how it is programmed in menu F7 PRT
HOLD: It serves to accumulate during a short period of time the weight showed in
screen.
key. Options: 2%, 4%, 10%, 20%, 50%, 100%
ENG
FR
ES
27