TROUBLESHOOTING
The appliance has been tested before being put into
service. The information provided below is intended
to assist in the identification and correction of any
anomalies and malfunctions which might occur dur-
ing use. The user can solve some of these prob-
Fault
The heating elements do not
come on.
The appliance does
not heat up.
Electronic circuit board
does not switch on.
TABLE OF ALARM INDICATIONS
Alarm
EO
EOC
)4
E2
'"
$%
AL1
&2
%3
%NGLISH
FAULT
lems himself, but for others specific technical
knowledge or skill is required, and so they must only
be carried out by qualified staff with recognised ex-
perience acquired in the specific sector of operation.
Causes
Electrical connection not made
correctly.
Safety thermostat tripped.
Switch faulty.
Contactor not receiving power or
faulty.
Electrical connection error.
Cause
Sensor has short-circuited;
electrical connection faulty.
Electronic control device faulty.
Loss of data set on the electronic
circuit board.
The maximum permitted
temperature values have been
exceeded; break in sensor
circuit.
- 10 -
Remedies
Check the connection of the
electrical wires.
Carry out the appliance reset
(see page 14).
Replace the switch.
Check the thermostat and activate
any start-up enabling device.
Check or replace the contactor
coil.
Check or swap the phase wire
connections.
Remedy
Contact the after-sales service.
Contact the after-sales service
Switch the appliance off and
back on; if the problem persists,
call the after-sales service
Wait for the oil to cool down; if
the problem persists, call the
after-sales service.