17 Troubleshooting

17 Troubleshooting

17.1 Troubleshooting the Blower and Battery

Condition
LEDs on Battery
Blower does not start
1 LED flashes
when switched on
green.
1 LED glows red.
3 LEDs flash red.
3 LEDs glow red.
4 LEDs flash red
Blower cuts out
3 LEDs glow red.
during operation
0458-711-9621-A
Cause
Battery has low charge.
Battery too hot or too cold. ► Pull the connecting cable plug out of the socket.
There is a malfunction in
the blower.
Blower too hot.
There is a malfunction in
the battery.
No electrical contact
between blower and
battery.
Blower or battery damp.
Blower too hot.
Remedy
► Recharge the battery fully as described in the
instruction manual for the STIHL AL 101, 300, 500
chargers.
► Allow battery to cool down / warm up.
► Pull connecting cable plug out of the socket and
then refit it.
► Switch on the blower.
► If 3 LEDs continue to flash red: Do not use the
blower and contact your STIHL servicing dealer for
assistance.
► Pull the connecting cable plug out of the socket.
► Allow blower to cool down.
► Pull connecting cable plug out of the socket and
then refit it.
► Switch on the blower.
► If 4 LEDs continue to flash red: Do not use the
battery and contact your STIHL dealer for
assistance.
► Pull connecting cable plug out of the socket and
then refit it.
► If blower still does not start when switched on:
Check the battery as described in the STIHL AR
battery's instruction manual or in the user
instructions for the "AP belt bag with connecting
cable".
► Allow blower or battery to dry.
► Pull the connecting cable plug out of the socket.
► Allow blower to cool down.