3.1.2

Symbols and their meanings

The symbols used on the control panel have the following meanings:
The welding unit is set to TIG welding. The maximum current is set at 170 A for
BOOSTER.PRO 170 and at 210 A for BOOSTER.PRO 210.
The welding unit is set to electrode welding with Fuse Hold function. The
maximum current is set at 140 A for BOOSTER.PRO 170 and at 160 A for
BOOSTER.PRO 210.
The welding unit is set to electrode welding with the BOOSTER function. The
maximum current is set at 150 A for BOOSTER.PRO 170 and at 170 A for
BOOSTER.PRO 210.
Open-circuit voltage is available at the torch or the electrode holder.
If this symbol flashes, the internal monitoring system has tripped. Switch the
mains switch off and on to reset the unit. Please inform the REHM Customer
Service Department of this.
Temperature indicator. The yellow LED lights up when the maximum permitted
temperature of the unit is exceeded. As long as the LED is lit, the output current
is switched off. After the unit has cooled down, the LED goes out and welding
can be restarted automatically. If this symbol flashes, the internal monitoring
system has tripped. Switch the mains switch off and on to reset the unit. Please
inform the REHM Customer Service Department of this.
3.2

"+" marking on the welding current socket

The "+" sign indicates the positive pole of the welding current source.
The earth cable is connected to this socket for TIG welding.
-
3.3
"

" marking / TIG symbol on the welding current socket

The "-" sign indicates the negative# pole of the welding current source.
The torch is connected to this socket for TIG welding.
4

Mains connection

The welding unit is fitted with a protective contact plug. The unit is
operated with fuses or circuit breakers with a rated current of 16A. When
the unit is switched ON, the main switch at the back of the unit is lit up.
If the BOOSTER.PRO is switched on and off frequently (in quick
succession), the unit may be switched to the protective mode. In this
mode, the unit cannot be started and the green lamp is switched on and
off. In this case, switch the unit off and wait for approx. 2 minutes. The
unit can then be restarted.