5. TROUBLE-SHOOTING
5.1 TROUBLE-SHOOTING INFORMATION.
IMPORTANT!!!
Electrical subassemblies may be replaced only by an authorised service technician.
It must be made a principle to disconnect the power cable from the power supply before
electrical components are replaced.
It must be made a principle to disconnect the power cable from the power supply before
electrical components are replaced.
FAULT
The air in the chamber of the
distributor does not heat up, the
switches and the thermoregulator
are activated, the control lamp is
off.
The air in the chamber is
insufficiently heated.
The thermostat signalling lamp
does not switch on though the air
heats up.
The guarantee does not cover the following:
Bulbs, rubber elements, heating elements damaged by boiler scale, panes, any mechanical
damage or any damage caused by improper use of the device in violation of the instructions.
In case of a fault, remove the food kept in the device to prevent it from going bad.
EDENOX is not responsible for any commodities wasted as a result of a fault.
9
edenox.com
POSSIBLE CAUSE
- Power supply failure.
- The terminals of the conductors
loosened on the power strip.
- The thermoregulator or the
thermal switch is damaged.
- The switches are damaged.
- Some heating elements are
disconnected.
- Heating elements are damaged.
- Control lamp burnt out.
- The electrical circuit of the
control lamp is open.
Before disposing of the device, check its
technical condition.
In particular, check the construction elements
which may cause leakage when disposed of.
Different parts of the device are disposed
differently, depending on their features (e.g.
metals, oils, lubricants, plastic, rubber, etc.).
REMEDY
Connect to power supply.
Appropriately fix the conductors to
the power strip.
Replace the damaged components.
Check that the heating elements
are properly connected.
Replace the damaged components.
Replace the control lamp.
Repair the wires of the control
lamp.