2.5 INSTALLATION AND ASSEMBLY.

The distributor should be installed in the following order:
 remove the protective film from all metal surfaces; the distributor must be installed in a well
ventilated room, under a ventilation hood, if possible; it can be located on a standalone base
or as part of a row consisting of other kitchen devices as well;
 the distributor should be connected to the power supply in compliance with applicable
regulations;
 install and connect the device in such a way that live wires cannot be accessed without tools;
the fuses of the power system of the distributor should be designed for 10 A current;
 put the distributor in a sufficiently prepared location; the height and the levelling of the device
should adjusted before it is installed on the base;
 connect the earth system of the device to the earth bar in such a way that it cannot be
disconnected inadvertently or unexpectedly; the power cable should contain a protective
conductor;
 to connect the distributor, use a cable of an appropriate length, so that it can hang freely from
the device (on no account may it be tight) when firmly and permanently attached to the
terminals of the connection block and the terminals of the power plug,
The conductor cross-section area of the power cable for the DPC-28 and DPC-34 distributors should
not be smaller than 1.5 mm
2.6 CONNECTIONS (ELECTRICITY, GAS, AND WATER).
The power cable used with the device should have 3 cords, the diameters of which may not be
smaller than suggested in the manual.
Designed to be powered by 230V, 50-60Hz mains power, the device's power cable is equipped
with a PE protective conductor.
The electrical connection is at the base of the device.
WARNING!!!
Prior to first use, it is necessary to remove the protective substance from the surfaces of the
distributor by wiping them with a soft cloth moistened with soapy water.
5
edenox.com
2
(recommended cable - PCG 3 x 1.5 mm
ENGLISH
2
).