10.6
STOVE ADJUSTMENT
The stove is adjusted according to the chimney flue and used pellets datas, as per technical characteristics
(see FEATURES page 98). If the datas do not correspond, the authorized technician can adjust the stove.
EN
• If the pellet is small in size and with a greater calorific power, (for example: encrusted burning pot),
the pellet drop must be decreased from the menu "SET FLAME", press P3 "PELLET TYPE", press P3 again
"PELLET LOAD" and with P2 key decrease the pellet quantity from -1 (which is -2%) till -9 (which is -18%).
• If the chimney flue has a lower draught (for example: weak flame, sooty glass) the revolutions of the
geared motor must be increased from the menu "SET FLAME", press P5 "CHIMNEY TYPE", press P3 "FUME-
FAN CHIMNEY" and with P1 key increase the fume fan revolutions from +1 (which is +5%) till +9 (which is
+30%).
• If the chimney flue has a greater draught (for example: because of pellets fall on the burning pot)
decrease the fume fan revolutions from -1 to -9.
10.7
FAILED IGNITION
If the pellets do not burn, the failed ignition will be indicated by the alarm "FAILED IGNITION".
• If the room temperature is lower than 10°C, the plug is not able to bear the ignition stage. To support
it please insert some pellets in the burning pot and a piece of burning firelighter igniter material on the
pellets (for example firelighters cubes).
• Too much pellets in the burning pot, or humid pellet, or sooty burning pot make ignition difficult and
create dense white smoke which is harmful to health and can cause explosions on the combustion
chamber. It is therefore necessary not to stand in front of the stove during ignition stage if dense white
smoke is present.
10.8
POWER FAILURE
• After a black-out lower than 5 seconds, the stove turns back to the power which was settled.
• After a black-out of more than 5 seconds, the stove enters the "COOLING WAIT" phase. Completed this
phase, it starts automatically up with the different phases (see START UP page 77).
10.9
TEMPERATURE SETTING
• To modify the ambient temperature it is sufficient to press P1 and P2 keys according to the desired
temperature inside the menu "SET TEMP AMBIENT".
• To see the set temperature, press once P1 key.
10.10
FUME TEMPERATURE
To check the fume temperature at the exhaust it is sufficient to keep pressed P2 key.
78
Pay attention if the value is positive or negative..
After a failed ignition the burning pot must be empty from the amassed pellets, before
starting the stove up again.
If after some months the flame appears weak and/or orange colored or the glass tends
to blackens and the burning pot to become encrusted, clean the stove, clean the
fume conduit and the chimney flue.
CLOE - SQUARE