Parameter Name
No.
Sramp Jerk 1
0493
Rate of change of acceleration for the first segment of the curve in units of percent per second³, i.e. if the full speed of the machine is
1.25m/s then the jerk will be:
1.25 x 50.00% = 0.625m/s³
Sramp Jerk 2
0494
Rate of change of acceleration in units of percent per second³ for segment 2
Sramp Jerk 3
0495
Rate of change of acceleration in units of percent per second³ for segment 3
Sramp Jerk 4
0496
Rate of change of acceleration in units of percent per second³ for segment 4
Ramp Hold
0497
When TRUE the output of the ramp is held at its last value
Ramping Active
0498
Set TRUE when ramping.
Ramp Spd Setpoint Input
0499
Input speed setpoint to the ramp
AC30 series Variable Speed Drive
Path
Parameters::Motor Control::Ramp
Parameters::Motor Control::Ramp
Parameters::Motor Control::Ramp
Parameters::Motor Control::Ramp
Parameters::Motor Control::Ramp
Parameters::Motor Control::Ramp
Parameters::Motor Control::Ramp
Parameter Reference
Default
Range
10.0
0.0 to 100.0
10.0
0.0 to 100.0
10.0
0.0 to 100.0
10.0
0.0 to 100.0
FALSE
x.x
-200.0 to 200.0
D-153
Units
Writable
ALWAYS
%/s³
ALWAYS
%/s³
ALWAYS
%/s³
%/s³
ALWAYS
ALWAYS
NEVER
NEVER
%