between them. For a detailed description of both response profiles, see Section 5.1 Possible
signal combinations.
With every activation of the E-MAG Control, the signals of the "Blue Profile" indicate the status
as follows:
Signal
Status
Lock closed
Lock open
Signal table 2: Confirmation of the activation with status indication according to the "Blue Profile"
4.3 Energy-saving mode
With every opening of the lock, the E-MAG Control switches into the energy-saving mode. The
electronics reactivates automatically when the lock again closes.
If neither the direct start button nor the remote control are activated for more than two hours
with a closed lock, the system shuts off automatically. In order to reactivate the E-MAG Control,
press briefly on the direct start button of the electronic control unit. The start sequence will set
on shortly after letting go of the key. Once the start sequence has finished, the E-MAG Control
is again ready for operation. The Blue Profile is active.
E-MAG Control
Light
3 x deep, short
Green
3 x high, long
Red
Sound
Putting into operation
Vibration
3 x short
3 x long
Ottobock | 25